English
Language : 

MLX92241 Datasheet, PDF (5/16 Pages) Melexis Microelectronic Systems – 2-Wire Hall Effect Switch
MLX92241-AAA
2-Wire Hall Effect Switch
4 General Electrical Specifications
DC Operating Parameters VDD = 2.7 to 24V, TJ = -40°C to 165°C (unless otherwise specified)
Parameter
Symbol Test Conditions
Min Typ(1)
Supply Voltage
VDD
Operating
2.7
-
Reverse Supply Current
IDDREV VDD = -16V
OFF Supply Current
IOFFLow VDD = 3.5 to 24V
2
3.3
OFF Supply Current
IOFFHigh VDD = 3.5 to 24V
5
6
ON Supply Current
ION
VDD = 3.5 to 24V
12 14.5
Safe Mode Supply Current
ITP
Thermal Protection activated
-
-
Supply Current Rise/Fall Time (2)
Power-On Time (3,4,5)
tRISE/FALL VDD = 12V, CLOAD = 50pF to GND
tON
VDD = 5V, dVDD/dt > 2V/us
0.1
0.3
-
40
Chopping Frequency
fCHOP
260 340
Delay time (2,6)
Output Jitter (p-p) (2,7)
Average value for 1000 successive
tD
switching events @10kHz, Square wave -
7.5
with B ≥ 3*BOPMAX, tRISE = tFALL ≤20us
Square wave with B ≥ 3*BOPMAX over
tJITTER 1000 successive switching events
-
±3.3
@1kHz
Maximum Switching Frequency (2,8) fSW
B ≥ 3*BOPMAX and square wave
magnetic field
30
50
Under-voltage Lockout Threshold VUVL
-
2
Under-voltage Lockout Reaction
time (2)
tUVL
-
1
Thermal Protection Threshold
TPROT Junction temperature
-
190 (9)
Thermal Protection Release
TREL Junction temperature
-
180 (9)
Safe Mode Supply Current
ITP
UA Package Thermal Resistance RTH
TSOT Package Thermal Resistance RTH
Thermal Protection activated
Single layer (1S) Jedec board, zero
LFPM
Single layer (1S) Jedec board, zero
LFPM
-
-
200
300
Max
24
1
5
6.9
17
0.8
1
70
-
-
-
-
2.7
-
-
-
0.8
Units
V
mA
mA
mA
mA
mA
μs
μs
kHz
µs
µs
kHz
V
µs
°C
°C
mA
°C/W
°C/W
1 Typical values are defined at TA = +25°C and VDD = 12V
2 Guaranteed by design and verified by characterization, not production tested
3 The Power-On Time represents the time from reaching VDD = VPOR to the first refresh of the supply current state.
4 Power-On Slew Rate is not critical for the proper device start-up.
5 B>BOPmax + 1 mT for direct output sensors, or B<BRPmin - 1 mT.
6 Delay Time is the time from magnetic threshold reached to the start of the supply current switching.
7 Output jitter is the unpredictable deviation of the Delay time
8 Maximum switching frequency corresponds to the maximum frequency of the applied magnetic field which is detected without loss of pulses
9 TPROT and TREL are the corresponding junction temperature values.
390109224100 Rev. 1
Page 5 of 16
June/13