7 Electrical Specifications
All parameters are preliminary for TA = 25 ˚C, VDD =3V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ
Max Units
External supply
Supply current
Supply current
(programming)
Supplies
VDD
IDD
No load
2.6
3
1
IDDpr
No load, erase/write EEPROM
operations
1.5
3.6
V
2
mA
2.5
mA
Sleep mode supply
current
Isleep
no load
1
2.5
5
uA
Sleep mode supply
current
Isleep
Full temperature range
1
2.5
6
uA
Power On Reset
POR level
VPOR_up
Power-up (full temp range)
1.4
1.75
1.95
V
POR level
VPOR_down Power –down (full temp range)
1.3
1.7
1.9
V
POR hysteresis
VPOR_hys
Full temp range
0.08
0.1
1.15
V
VDD rise time (10% to
90% of specified
supply voltage)
TPOR
Ensure POR signal
20
ms
Output valid
Tvalid
After POR
0.15
s
Pulse width modulation1
PWM resolution
PWMres
Data band
10
bit
PWM output period
PWMT,def
Factory default, internal oscillator
factory calibrated
1.024
ms
Internal oscillator factory
PWM period stability dPWMT
calibrated, over the entire
operation range and supply
-4
voltage
+4
%
Output high Level
Output low Level
Output drive current
Output sink current
Continued next page.
PWMHI
PWMLO
IdrivePWM
IsinkPWM
Isource = 2 mA
Isink = 2 mA
Vout,H = VDD - 0.8V
Vout,L = 0.8V
VDD-0.25
V
VSS+0.25
V
4.5
mA
11
mA
3901090616
Rev 002
Page 6 of 36
Data Sheet
August 20, 2012