English
Language : 

MLX90816 Datasheet, PDF (4/6 Pages) Melexis Microelectronic Systems – Discrete Absolute Pressure Sensor
MLX90816
Discrete Absolute Pressure Sensor
9. General Electrical Specifications
DC Operating Parameters TA = 25 oC, VDD = 5V, Pressure = 50 bar Full Scale unless otherwise specified.
Parameter
Sensitivity
Bridge Resistance
Offset
Non linearity (best fit)
Symbol
S
Rb
O
NL
Min
0.42
3
-30
-0.2
Max
.58
5.5
30
0.2
Units
mV/V/bar
kΩ
mV
%FS
Thermal Hysteresis
Hyst
-0.2 0.2
%FS
Thermal coefficient of
Span
TCS
Thermal coefficient of
Offset
TCO
-0.23 -0.15 %FS/˚C
-0.06 0.06 %FS/˚C
Thermal coefficient of
bridge resistance
TCR
0.30 0.40
Table 3: Electrical specifications
%FS/˚C
The MLX90816 can also be used with full scale pressures other than 50bar (30 to 50bar). Contact Melexis for
detailed information on the IC performance at different full scale pressures.
10. Application Information
The MLX90816 is a very reliable discrete absolute pressure sensor fully automotive qualified. Like all Melexis
pressure sensors it has been qualified beyond typical semiconductors qualification standards. For harsh
media applications the MLX90816 can be used in a fluid filled housing.
If the application requires an amplified conditioned output the MLX90816 can be used in combination with
Melexis sensor interfaces IC like the MLX90328 and the MLX90329. By programming some calibration
settings in the sensor interface IC the sensitivity and offset variations from part to part as well as their
variations over temperature can be compensated for.
3901090816
Rev 1
Page 4 of 6
Data Sheet
Dec 2014