7. Absolute Maximum Ratings
Parameter
Supply Voltage (overvoltage)
Operating Temperature Range
Storage Temperature Range
Burst Pressure
Sym
bol
Min Value
Max Value
V
10
T
-40
150
T
- 55
150
200
Table 1: Absolute maximum ratings
Units
V
°C
°C
Bar
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum
rated conditions for extended periods may affect device reliability.
8. Die Information
Figure 2 Chip Dimensions and bond pad positions (all dim. in μm)
Bond Pads opening size (x, y) in
um
(330,155)
Die thickness (μm)
700
Bond
Pad
Function / Description
Vexc +
Supply voltage
Vout +
Positive output voltage
Vout -
Negative output voltage
Vexc -
Ground connection
Table 2: Bond pads description