English
Language : 

MLX90251_12 Datasheet, PDF (4/20 Pages) Melexis Microelectronic Systems – Programmable Linear Hall Effect Sensor
MLX90251
Programmable Linear Hall Effect Sensor
3 Glossary of Terms
Term
mT (milli-Tesla)
VOQ (Output Quiescent
Voltage)
Sensitivity
TempCo (Sensitivity
Temperature Compensation)
PTC (Programming Through
the Connector)
MSB
LSB
Explanation
Unit of measurement for magnetic flux density. 1mT is equal to 10 Gauss.
Output voltage at zero magnetic field, VOUT for B = 0 mT.
Change in output voltage versus change in magnetic field (∆ VOUT / ∆ B)
Change in Sensitivity over temperature.
Listed in units of ppm / °C (where 100ppm / °C. = 0.01% / °C)
Melexis in-circuit programming protocol.
Most Significant Bit.
Least Significant Bit.
4 Maximum Ratings
Parameter
Maximum Supply Voltage, VDD_MAX (over
Voltage)
Maximum Supply Current, IDD_MAX
(Over Voltage)
Reverse Voltage, VDD_REV
Reverse Supply Current, IDD_REV
Positive Output Voltage, VOUT_MAX
Positive Output Current, IOUT_POS_FAULT
Reverse Output Voltage, VOUT_REV
Reverse Output Current, IOUT_REV_FAULT
Operating Ambient Temperature Range, TA
Storage Temperature Range, TS
Magnetic Flux Density
Table 2: Absolute Maximum Ratings
Units
30 V
50 mA
- 15 V
- 85 mA
24 V
40 mA
- 0.7 V
-50 mA
-40°C to 150°C
-55°C to 165°C
Infinite
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
3901090251
Rev 012
Page 4 of 20
Data Sheet
Oct/2012