English
Language : 

MLX90251 Datasheet, PDF (3/22 Pages) Melexis Microelectronic Systems – Programmable Linear Hall Effect Sensor
MLX90251
Programmable Linear Hall Effect Sensor
3 Glossary of Terms
mT (milli-Tesla) = Unit of measurement for magnetic flux density. 1mT is equal to 10 Gauss.
VOQ (Output Quiescent Voltage) = Output voltage at zero magnetic field, VOUT for B = 0 mT.
Sensitivity = Change in output voltage versus change in magnetic field. ∆ VOUT / ∆ B.
TempCo (Sensitivity Temperature Compensation) = Change in Sensitivity over temperature. Listed
in units of ppm / °C (100ppm / °C. = 0.01 % / °C.).
PTC (Programming Through the Connector) = Melexis in circuit programming protocol.
MSB = Most Significant Bit.
LSB = Least Significant Bit.
4 Maximum Ratings
Parameter
Maximum Supply Voltage, VDD_MAX (over
Voltage)
Maximum Supply Current, IDD_MAX
(Over Voltage)
Reverse Voltage, VDD_REV
Reverse Supply Current, IDD_REV
Positive Output Voltage, VOUT_MAX
Positive Output Current, IOUT_POS_FAULT
Reverse Output Voltage, VOUT_REV
Reverse Output Current, IOUT_REV_FAULT
Operating Ambient Temperature Range, TA
Storage Temperature Range, TS
Magnetic Flux Density
Table 2: Absolute Maximum Ratings
Units
30 V
50 mA
- 15 V
- 85 mA
24 V
40 mA
- 0.7 V
-50 mA
-40°C to 150°C
-55°C to 165°C
Infinite
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
3901090251
Rev 009
Page 3 of 22
Data Sheet
Nov/06