10.7 Filter (FILTER)
The MLX90251 includes two programmable low-pass filters located within the chopper amplifier stages. The
two low-pass filters are controlled through a 4 bit parameter, FILTER. The FILTER value 0 corresponds to
minimum filtering, maximum speed (impulse response time), and maximum output noise. The value 15
provides the maximum filtering, minimum speed, and minimum output noise. It is important to note the noise
is also linked to the gain settings. The FILTER parameter needs to be adjusted to achieve optimal
performance. The next table shows typical values the cut-off frequency at -3 dB versus FILTER and RG
parameters. FILTER values from 8 to 11 are not used. For most applications FILTER values 7 or 15 are
recommended.
Cut-off frequency at -3 dB (Hz) – Typical
Filter
MLX90251-0
MLX90251-1
MLX90251-2
Rough Gain 0…3 Rough Gain 4…7 Rough Gain 8…11
0
22900
14300
7000
1
19500
11450
5550
2
12300
10000
3000
3
10400
6750
2100
4
7450
3900
1500
5
5850
2900
1125
6
5700
2700
1350
7
5050
2550
1380
8
Not used
9
Not used
10
Not used
11
Not used
12
2200
840
565
13
1000
480
470
14
920
380
290
15
800
330
250
Table 11: Cut-off Frequency versus FILTER and RG Parameters
MLX90251-3
Rough Gain 12…15
3850
2950
2300
1100
850
860
715
650
250
190
155
135
10.8 Sensitivity Temperature Compensation (TC, TCW, TC2)
The change in the device's Sensitivity versus temperature is defined as the Sensitivity Temperature
Compensation, TempCo. In an application the slope output transfer characteristic is often affected by
temperature. Fluctuations in temperature can cause variations in the air gap, mechanical alignment and
magnetic field. The Sensitivity Temperature Compensation feature compensates for these effects.
Three parameters, TC, TCW, TC2 are used for adjustment of the TempCo. The TCW is used to adjust the
TempCo range, TC is for fine adjustment of the TempCo value, and TC2 effects the TempCo linear response.
To simplify use of these parameters Melexis stores a look up table within the EEPROM of each device. The
look up table is optimized for each device by characterizing the unit over temperature at final test.
The value of TempCo is often determined by the magnet. In the application the TempCo is adjusted to
compensate for the temperature coefficient of the magnet. To adjust the value the look up table is read from
the device. The parameters are then calculated to match the desired value. The Melexis PTC hardware and
software tools contain built in functions for programming the TempCo.