MLX90620
16x4 IR array
8.2 MLX90620 address map
The MLX90620 address map is shown below:
0x00
RAM
0x91
0x92 Configuration registers
0x93
0x93
Not used
0xFF
Figure 16 Address map
8.2.1 RAM
The on chip 146x16 RAM is accessible for reading via I2C. The RAM is used for storing the results of
measurements of pixels and Ta sensor and is distributes as follows:
64 words for IR sensors. The data is in 2’s complement format (see 7.2.2)
1 word for measurement result of PTAT sensor. The data is 16 bit without sign. (see 7.2.1)
The memory map of the RAM is shown below:
RAM Address
0x00
0x01
0x02
0x03
0x04
0x05
…
0x3B
0x3C
0x3D
0x3E
0x3F
0X40
…
0X8F
0x90
0x91
RAM variable description
IR sensor (0,0) result
IR sensor (1,0) result
IR sensor (2,0) result
IR sensor (3,0) result
IR sensor (0,1) result
IR sensor (1,1) result
…
IR sensor (3,14) result
IR sensor (0,15) result
IR sensor (1,15) result
IR sensor (2,15) result
IR sensor (3,15) result
NA
…
NA
PTAT sensor result
TGC sensor result
Table 9: Result address map
For IR sensors results, the addressing can be summarized:
IR(x,y) is on address:
IR(x, y)address x 4.y
3001090620
Rev 4.0
Page 21 of 40
Datasheet IR16x4
19 September 2012