English
Language : 

MLX90217 Datasheet, PDF (2/8 Pages) List of Unclassifed Manufacturers – Hall-Effect Cam Sensor
MLX90217
Hall-Effect Cam Sensor
MLX90217 Electrical Specifications
DC Operating Parameters TA = -40oC to 150oC, VDD = 3.5V to 24V (unless otherwise specified).
Parameter
Supply Voltage
Symbol Test Conditions
VDD
Operating
Min Typ Max Units
3.5
-
24
V
Supply Current
IDD
VDD = 12V
1.5 3.0 4.5
mA
Supply Current
IDD
VDD = 3.5V to 24V
1
-
6
mA
Leakage Current
ILEAK
VOUT = 3.5V to 24V
-
-
10
µA
Output Current
IOUT
Operating
-
-
25
mA
Output Saturation Voltage
VSAT
VDD = 12V, IOUT = 25mA
-
-
600
mV
Output Short Circuit Current
IFAULT
Fault
50 100 150
mA
Output Short Circuit Shutdown TFAULT Fault
100
-
200
µS
Clock Frequency
fCLK
Operating
300 500 800
kHz
Output Rise Time
tr
VDD=12V R1 = 880W C1 = 20pf
-
400
nS
Output Fall Time
tf
VDD=12V R1 = 880W C1 = 20pf
-
400
nS
Bandwidth
BW
Operating
-
-
15
kHz
Thermal Resistance
RTH
Operating
-
-
200 oC/Watt
MLX90217 Magnetic Specifications
DC Operating Parameters TA = -40oC to 150oC, VDD = 3.5V to 24V (Unless otherwise specified)
Parameter
Back Bias Range
Symbol Test Conditions
BBIAS
Operating
Min Typ Max
-30
-
400
Units
mT
Linear Region
VDD = 12V
50
-
500
mT
Hysteresis
Bhys
VDD = 3.5V to 24V
1.8
3.5
10
mT
Notes: 1mT=10Gauss
3901090217
Rev. 009
Page 2
Jun/04