English
Language : 

MLX90215 Datasheet, PDF (2/10 Pages) List of Unclassifed Manufacturers – Precision Programmable Linear Hall Effect Sensor
MLX90215
Precision Programmable
Linear Hall Effect Sensor
MLX90215 Electrical Specifications
DC Operating Parameters TA = -40oC to 150oC, VDD = 5.0V (Unless otherwise specified)
Parameter
Supply Voltage
Symbol Test Conditions
VDD
Operating
Min Typ Max
4.5
5.0
5.5
Units
V
Supply Current
IDD
B = 0, VDD = 5V, IOUT = 0
2.5
4.0
6.5
mA
Output Current (1)
IOUT
VDD = 5V + 10%
-2
-
2
mA
Quiescent Output Voltage (2)
VOQ
10-Bit Programmable, B = 0
0.5
-
4.5
V
Output Voltage (1)
VOH
VDD = 5V, IOUT = -2mA
4.50 4.65
V
Output Voltage (1)
Sampling Rate
Bandwidth (3)
VOL
VDD = 5V, IOUT = 2mA
fSAMP RoughGain @ Max and Min
BW
RoughGain @ Min
0.35 0.50
V
4
-
40
kHz
-
1.300
kHz
Bandwidth (3)
BW
RoughGain @ Max
0.130
-
kHz
Step Response Time (6)
TRMIN RoughGain @ Min
25
-
µs
Step Response Time (6)
TRMIN RoughGain @ Max
250
µs
Offset Voltage Adjustment
Resolution
Offset Voltage Drift
over Temperature
Offset Voltage Drift (2)
over Temperature
Range of Sensitivity (7)
Peak to Peak Noise (4)
∆VOQ
B = 0, TA = 25oC , 1/2 Vdd = 1
B = 0, TA = 25oC , 1/2 Vdd = 0
∆VOQ/∆T B = 0, TA = -40oC to 150oC
S < 100mV/mT & VOQ > 0.75V
∆VOQ/∆T B = 0, TA = -40oC to 150oC
S > 100mV/mT & VOQ < 0.75V
s
13-Bit Programmable
-1.5
-
1.5
mV
-6.0
6.0
mV
-20
-
20
mV
-40
-
40
mV
5
-
140 mV/mT
8
25
60
mV
Output Resistance
Sensitivity Drift(5)
ROUT
TA = 25oC
6
Ω
-1
-
1
%
Notes:
(1) If output current and voltage specifications are exceeded, linearity will be degraded.
(2) If VOQ is programmed beyond these limits, the temperature compensation may become a problem at high
temperatures. It is not recommended to program values of VOQ below 1V or above 4V when sensitivity exceeds 100
mV/mT. Temperature instability can occur on some devices under these conditions.
(3) Bandwidth is related to the sample rate and ROUGHGAIN. Bandwidth is estimated by (sample rate / 30)
(4) Peak to Peak Noise is a function of ROUGHGAIN setting. See page 5, Peak to Peak Noise versus Sensitivity.
(5) Sensitivity drift is independent of other parameters and does not include individual tolerances (∆VOQ or ∆VOQ/∆T).
The tolerance for sensitivity ±1% of its initial value. This does not include tolerance stack-up.
(6) If the step input occurs in the middle of a sample interval, the small signal response delay will double. For
ROUGHGAIN values less than or equal to 3, response time may be limited by the slew rate.
(7) 1 mT = 10 Gauss
Melexis Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. Melexis does not
assume any liability arising from the use of any product or application of any product or circuit described herein.
3901090215
Rev 007
Page 2
9/09/03