14.2.6. CLAMPING Parameters
The clamping levels are two independent values to limit the output voltage range. The CLAMPLOW
parameter adjusts the minimum output voltage level. The CLAMPHIGH parameter sets the maximum
output voltage level. Both parameters have 16 bits of adjustment and are available for both LNR modes.
In analog mode, the resolution will be limited by the D/A converter (12 bits) to 0.024%VDD. In PWM mode,
the resolution will be 0.024%DC.
14.3. Identification
Parameter
MELEXISID1
MELEXISID2
MELEXISID3
CUSTOMERID1
CUSTOMERID2
CUSTOMERID3
CUSTOMERID4
Value
0 … 65535
0 … 65535
0 … 65535
0 … 65535
0 … 65535
0 … 65535
0 … 65535
Identification number: 64 bits (4 words) freely useable by Customer for traceability purpose.
Those 64 bits are only available if the 3pts-LNR. For the 16-Pts LNR, the corresponding EEPROM area of
CUSTOMERID1,2,3 are used by the LNR function.
14.4. Sensor Front-End
Parameter
HS
MAPXYZ
k (or SMISM)
GAINMIN
GAINMAX
Value
0 = Slow mode
1 = Fast mode
0 .. 5
0 .. 65535
0 … 41
14.4.1. HIGHSPEED Parameter
The HIGHSPEED parameter defines the main frequency for the DSP.
• HIGHSPEED = 0 selects the Slow mode with a 6.5 MHz master clock (nominal).
• HIGHSPEED = 1 selects the Fast mode with a 10.0 MHz master clock (nominal).
For better noise performance, the Slow Mode must be enabled.
MLX90360
Rev. 009
Page 19 of 35
Datasheet
Dec/13