English
Language : 

MLX75031 Datasheet, PDF (10/67 Pages) Melexis Microelectronic Systems – Optical Gesture & Proximity Sensing IC
MLX75031
Optical Gesture & Proximity Sensing IC
with Integrated LED Drivers
Datasheet
7. Sensor Interface Specific Specifications
The following characteristics are valid over the full temperature range of TA = -40°C to +105°C and a supply
range of VSUP = 6.18V and VCCD = VCCA = 3.135..3.465V unless otherwise noted.
Active Light Channels (Photodiode A & B)
Parameter
Symbol Test Conditions Min Typ Max Units
Optical transfer ratio
OTR = I LED
30
I PD
DC sunlight current in the
photodiode
Isun
0
Fast full scale transition at Isunmax
tsunrise
3.5
Min. relative active light
modulation
(referred to received IR signal)
∆I PD _ min
I PD
- 20 µs LED pulse
- PD pulsed current
≥ 20µA, - 25°C
- DC sun constant
- response per
channel 2.5ms
Dynamic range of active light events
(referred to received IR signal)
∆IActiveLight
12000
900 µA
ms
1 5 (*) %
80
%
Active light repetition time
Acive light measurement
channel A, channel B
trep_activelight
2.5
ms
2.5
ms
LED pulse duration range
Max. input capacitance PDA & PDB
DC light measurement range
DC light measurement offset
DC light measurement slope
DC light measurement
inearity error
t0
CPDA, CPDB
IDC range
IDC offset
IDC sens
selectable via register 15-8%
0
IDC = 0uA & VDD=3.3V 1360 1960
28 35
IDC range: 0uA ->
900uA
5
30+8%
80
900
2460
44
8
µs
pF
µA
LSB
LSB/µA
%
DC light measurement word length
16
Bit
DC light measurement noise
for averaging of
8 measurements
3
Bit
Error condition Err_TIA
Critical error detected on TIA output, if TIA output outside 1.1V+/- (0.65 … 0.75V)
Table 4 : Active Light Channels Specification
(*) The 5% is really worst case condition, i.e. with OTR = 30 and Rshunt = 1Ohm,
this condition is not realistic and should be avoided in a the application
REVISION 001 – JANUARY, 2013
39010xxxxx
Page 10 of 10