English
Language : 

EVB71122_15 Datasheet, PDF (10/31 Pages) Melexis Microelectronic Systems – 300 to 930MHz Receiver Evaluation Board Description
EVB71122
300 to 930MHz Receiver
Evaluation Board Description
2.2.2 Calculation of LO1 and IF1 frequency for High Frequency Bands
Typical ISM band operating frequencies like 868.3 and 915MHz can be covered without changing the crystal
nor the VCO inductor.
Low-low injection should be used for the high frequency bands. First of all choose a PFD frequency fPFD
according to below table. The R counter values are valid for a 10MHz crystal reference. The PFD frequency
is given by fPFD = fRO /R.
Injection Type
fCH [kHz]
fPFD [kHz]
R
l-l
20
16
625
l-l
25
20
500
l-l
50
40
250
l-l
100
80
125
l-l
250
200
50
l-l
500
400
25
The second step is to calculate the missing parameters fLO1, fIF1, Ntot, N and A. While the second IF (fIF2), the
NLO2 divider ratio and the prescaler divider ratio P are bound to fIF2 = 2MHz, NLo2 = 4 (or 8) and P =32.
f LO1

N LO2
N LO2 
1
(f
RF

fIF2 )
f LO1

4
5
(f RF

2M Hz)
(8)
f IF1

f RF  N LO2fIF2
N LO2  1
f IF1

f RF
 8MHz
5
(9)
Finally N and A can be calculated with formula (5).
2.2.3 Counter Setting Examples for SPI Mode
To provide some examples, the following table shows some counter settings for the reception of the well-
known ISM and SRD frequency bands. The channel spacing is assumed to be fCH = 100kHz. In below table
all frequency units are in MHz.
Inj
fRF
fIF1
fLO1
Ntot
N
P
h-h 300 97.3 397.3 2980 93
32
h-h 315 102.3 417.3 3130 97
32
h-h 434 142 576 4320 135 32
h-h 470 154 624 4680 146 32
l-l 850 171.6 678.4 8480 256 32
l-l 868 175.2 692.8 8660 270 32
l-l 915 184.6 730.4 9130 285 32
l-l 930 187.6 742.4 9280 290 32
A
fPFD
R
4 0.133 75
26 0.133 75
0 0.133 75
8 0.133 75
0 0.08 125
20 0.08 125
10 0.08 125
0 0.08 125
fREF
fLO2
fIF2
10 99.3 2
10 104.3 2
10 144
2
10 156
2
10 169.6 2
10 173.2 2
10 182.6 2
10 185.6 2
39012 71122 01
Rev. 005
Page 10 of 31
EVB Description
Nov/15