English
Language : 

MG86FE104 Datasheet, PDF (86/134 Pages) Megawin Technology Co., Ltd – Interrupt controller
Table 15–9. Timer 1 Generated Commonly Used Baud Rates @ FSYSCLK=24.0MHz
TH1, the Reload Value
Baud Rate
T1X12=0 & SMOD2=0
T1X12=1 & SMOD2=0
SMOD1=0 SMOD1=1 Error SMOD1=0 SMOD1=1 Error
1200
204
152
0.16%
--
--
--
2400
230
204
0.16%
--
--
--
4800
243
230
0.16%
100
--
0.16%
9600
--
243
0.16%
178
100
0.16%
14400
--
--
--
204
152
0.16%
19200
--
--
--
217
178
0.16%
28800
--
--
--
230
204
0.16%
38400
--
--
--
--
217
0.16%
57600
--
--
--
243
230
0.16%
115200
--
--
--
--
243
0.16%
Table 15–10. Timer 1 Generated High Baud Rates @ FSYSCLK=24.0MHz
TH1, the Reload Value
Baud Rate
T1X12=0 & SMOD2=1
T1X12=1 & SMOD2=1
SMOD1=0 SMOD1=1 Error SMOD1=0 SMOD1=1 Error
230.4K
--
460.8K
--
691.2K
--
921.6K
--
--
--
243
230
0.16%
--
--
--
243
0.16%
--
--
--
--
--
--
--
--
--
--
86
MG86FE/L104 Data Sheet
MEGAWIN