3.Remote Control
The PSU can be turned ON/OFF by using the
"Remote Control" function.
Between RC+(pin3) and RC-(pin4) Output Status
SW ON (Short)
OFF
SW OFF (Open)
ON
CN100
21
10 9
CN100
2 AUX AUXG 1
RC- RC+
GND CS
GND DC-OK
10 -S +S 9
SW
Fig 3.1
4.Current Sharing with Remote Sensing (Only for 24V, 36V and 48V)
HRPG-600 has the built-in active current sharing function and can be connected in parallel to provide higher output power :
(1)Parallel operation is available by connecting the units shown as below.
(+S,-S,CS and GND are connected mutually in parallel).
(2)Difference of output voltages among parallel units should be less than 2%.
(3)The total output current must not exceed the value determined by the following equation.
(output current at parallel operation)=(Rated current per unit) (Number of unit) 0.9
(4)In parallel operation 2 units is the maximum, please consult the manufacturer for applications of more connecting in parallel.
(5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
PSU1
PSU2
PSU3
PSU4
CN100
-V
+V
CN100
-V
+V
CN100
-V
+V
CN100
-V
+V
PSU1
CN100
1 AUXG RC+ CS DC-OK +S 9
2 AUX RC- GND GND -S 10
PSU2
CN100
1 AUXG RC+ CS DC-OK +S 9
2 AUX RC- GND GND -S 10
PSU3
CN100
1 AUXG RC+ CS DC-OK +S 9
2 AUX RC- GND GND -S 10
PSU4
CN100
1 AUXG RC+ CS DC-OK +S 9
2 AUX RC- GND GND -S 10
+V -V
LOAD
Sense lines should
be twisted in pairs
Fig 4.1
Note : 1.In parallel connection, maybe only one unit (master) operate if the total output load is less than 2% of rated load condition.
The other PSU (slave) may go into standby mode and its output LED and relay will not turn on.
2.2% min. of dummy load is required.