English
Language : 

HRPG-600 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 600W Single Output with PFC Function
600W Single Output with PFC Function
HRPG-600 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in cooling fan ON-OFF control
Built-in DC OK signal
Built-in remote ON-OFF control
Standby 5V@0.3A
Built-in remote sense function
No load power consumption<0.75W (Note.7)
Current sharing up to 2400W (3+1) (24V,36V,48V)
5 years warranty
SPECIFICATION
MODEL
HRPG-600-3.3 HRPG-600-5 HRPG-600-7.5 HRPG-600-12 HRPG-600-15 HRPG-600-24 HRPG-600-36 HRPG-600-48
OUTPUT
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
RATED CURRENT
120A
120A
80A
53A
43A
CURRENT RANGE
0 ~ 120A
0 ~ 120A
0 ~ 80A
0 ~ 53A
0 ~ 43A
RATED POWER
396W
600W
600W
636W
645W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V
10.2 ~ 13.8V 13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.3%
0.3%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
24V
27A
0 ~ 27A
648W
150mVp-p
21.6 ~ 28.8V
1.0%
0.2%
0.5%
36V
17.5A
0 ~ 17.5A
630W
200mVp-p
28.8 ~ 39.6V
1.0%
0.2%
0.5%
48V
13A
0 ~ 13A
624W
240mVp-p
40.8 ~ 55.2V
1.0%
0.2%
0.5%
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.94/230VAC PF>0.99/115VAC at full load
INPUT EFFICIENCY (Typ.)
78.5%
82%
86%
88%
88%
88%
89%
89%
AC CURRENT (Typ.)
8.5A/115VAC 5A/230VAC
INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
PROTECTION
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V 57.6 ~ 67.2V
80 5 (TSW1)detect on heatsink of power transistor
OVER TEMPERATURE
90 5 (TSW2) detect on heatsink of power doide for 3.3V,5V,7.5V ; 100 5 (TSW2) detect on main power output choke for others
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V STANDBY
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)
DC OK SIGNAL
FUNCTION
REMOTE CONTROL
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
FAN CONTROL (Typ.)
Load 35 15% or RTH2 50 Fan on
WORKING TEMP.
-40 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
147.7K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
218*105*63.5mm (L*W*H)
1.58Kg;8pcs/13.6Kg/1.34CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) 0 ~ 8V or short.
File Name:HRPG-600-SPEC 2010-11-29