English
Language : 

HRP-450-3.3 Datasheet, PDF (3/3 Pages) Mean Well Enterprises Co., Ltd. – 450W Single Output with PFC Function
450W Single Output with PFC Function
HRP-450 series
Function Description of CN100
Pin No. Function Description
1 DC-OK DC-OK Signal is a TTL level signal, referenced to pin2(DC-OK GND). High when PSU turns on.
2
GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.
3
+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
4
-S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Function Manual
1.Remote Sense
The remote sensing compensates voltage drop on
the load wiring up to 0.5V.
CN100
21
43
CN100
2 GND DC-OK 1
4
3
-S +S
+S
(Pin3)
+-
LOAD
-S
(Pin4)
Fig 1.1
Sense lines should
be twisted in pairs
2.DC-OK Signal
DC-OK signal is a TTL level signal. High when PSU turns on.
Between DC-OK(pin5) and GND(pin6) Output Status
3.3 ~ 5.6V
ON
0 ~ 1V
OFF
CN100
21
43
Fig 2.1
CN100
2
1
GND DC-OK
4 -S +S 3
File Name:HRP-450-SPEC 2010-03-24