SPECIFICATION
MODEL
HRP-450-3.3 HRP-450-5 HRP-450-7.5 HRP-450-12 HRP-450-15 HRP-450-24 HRP-450-36 HRP-450-48
OUTPUT
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
RATED CURRENT
90A
90A
60A
37.5A
30A
CURRENT RANGE
0 ~ 90A
0 ~ 90A
0 ~ 60A
0 ~ 37.5A
0 ~ 30A
RATED POWER
297W
450W
450W
450W
450W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V
10.2 ~ 13.8V 13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.3%
0.3%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
24V
18.8A
0 ~ 18.8A
451.2W
150mVp-p
21.6 ~ 28.8V
1.0%
0.2%
0.5%
36V
12.5A
0 ~ 12.5A
450W
200mVp-p
28.8 ~ 39.6V
1.0%
0.2%
0.5%
48V
9.5A
0 ~ 9.5A
456W
240mVp-p
40.8 ~ 55.2V
1.0%
0.2%
0.5%
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
INPUT EFFICIENCY (Typ.)
80%
83%
86.5%
88%
89%
88%
89%
89.5%
AC CURRENT (Typ.)
5A/115VAC 2.4A/230VAC
INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.5mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V 57.6 ~ 67.2V
OVER TEMPERATURE
90 5 (70 5 5V only) (TSW1 : detect on heatsink of power transistor) ; 90 5 (TSW2 : detect on heatsink of power doide)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION DC OK SIGNAL
FAN CONTROL (Typ.)
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
Load 20 10% or RTH2 50 Fan on
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
139.9K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
218*105*41mm (L*W*H)
1.19Kg; 12pcs/15.3Kg/0.83CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-450-SPEC 2010-03-24