1000W Intelligent Single Output Battery Charger
PB-1000 series
SPECIFICATION
Features :
Controlled by microprocessor
2/3/8 stage charging selectable on output panel (Note 4)
Universal AC input / Full range
Built-in active PFC function PF>0.95
Protection: Reverse Polarity / Short circuit / Over voltage / Over temperature
Charger for lead-acid batteries
3 color LED loading indicator
Built-in remote ON-OFF control
2-Bank charger
Temperature compensation function
FAN on/off control (depends on charging current)
3 years warranty
..
MODEL
PB-1000-12
PB-1000-24
PB-1000-48
BOOST CHARGE VOLTAGE 14.4V
28.8V
57.6V
FLOAT CHARGE VOLTAGE 13.8V
27.6V
55.2V
OUTPUT CURRENT
60A
34.7A
17.4A
RECOMMENDED BATTERY
OUTPUT
200 ~ 600Ah
CAPACITY(AMP HOURS)(Note 3)
120 ~ 350Ah
60 ~ 175Ah
BATTERY TYPE
Open & Sealed Lead Acid
LEAKAGE CURRENT FROM
<1mA
BATTERY (Typ.)
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
85%
88%
89%
INPUT
POWER FACTOR (Typ.)
0.95/230VAC 0.98/115VAC at full load
AC CURRENT (Typ.)
12A/115VAC 5.2A/230VAC
INRUSH CURRENT (Typ.) 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER VOLTAGE
16 ~ 18V
32 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
64.5 ~ 69.5V
PROTECTION
80 5 (12V), 85 5 (24V,48V) (TSW1: detect on heatsink of power transistor)
OVER TEMPERATURE
85 5 (12V),75 5 (24V,48V) (TSW2 : detect on heatsink of o/p diode)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
SHORT CIRCUIT
YES, protected by internal circuit
REVERSE POLARITY
YES, protected by internal circuit
REMOTE CONTROL
Open: Normal work Short: Stop Charging
BATTER BANKS
2 banks (A & B)
FUNCTION FAST CHARGE
CHARGER OK
2 / 3 / 8 stage selectable
Relay contact rating(max.): 30V/1A resistive ; "Short" when the unit is working properly, "Open"when the unit is failure or the protection function is activating
OUTPUT OK
Relay contact rating(max.): 30V/1A resistive ; "Short" when the battery is full, "Open" when the battery is still charging
TEMPERATURE COMPENSATION By NTC, compensate both banks at the same time
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 2)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
127.4Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
300*184*70mm(L*W*H)
3.5Kg; 4pcs/15Kg/1.83CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
4. Please choose the "3 stage" selection when the charger is used to charge the batteries and power the loads in the same time.
File Name:PB-1000-SPEC 2011-01-18