English
Language : 

81840 Datasheet, PDF (7/12 Pages) List of Unclassifed Manufacturers – 128 Channel Multiplexer
128 Channel Multiplexer
81840
TABLE 5. 81840 ELECTRICAL TEST TABLE
PARAMETER
TEST CONDITIONS
SUBGROUPS
TEST LIMITS
UNITS
TA = 25°C TA = 125°C TA =-55°C
Leakage Current into off MUX
Output Channels, CLPx,
SP1OUT, SP2OUT, BYPASS,
POSITIVE, NEGATIVE,
+ID(OFF)
All VIN = 10V, CLPx,
SP1OUT, SP2OUT,
BYPASS, POSITIVE
NEGATIVE = 10V
All enables = 0.8V
All unused = 0.0V
Leakage Current into off MUX All VIN = -10V, CLPx,
Output Channels, CLPx,
SP1OUT, SP2OUT,
SP1OUT, SP2OUT, BYPASS, BYPASS, POSITIVE,
POSITIVE, NEGATIVE, -ID(OFF) NEGATIVE = 10V
All enables = 0.8V
All unused = 0.0V
Leakage Current into on MUX
Output Channels, CLPx,
SP1OUT, SP2OUT, BYPASS,
POSITIVE, NEGATIVE, -ID(ON)
Note: Sequence all inputs for
each output.
Output and Input Under
Test = 10V
All unused VIN = 10V
All enables = 0.8V
Leakage Current into on MUX
output Channels, CLPx,
SP1OUT, SP2OUT, BYPASS,
POSITIVE, NEGATIVE, ID(ON)
Note: Sequence all inputs for
each output
Output and Input Under
Test = -10V
All unused VIN = -10V
All enables = 0.8V
VREF
Input Voltage Low VIL2
VIN = 5.0V
Input Voltage High VIH2
VIN = 5.0V
Supply Current for
IS+
IS-
Standby Supply Current for
ISB+
ISB-
All enables = 0.8V
All enables = 0.8V
1, 2, 3
MIN MAX MIN MAX MIN MAX
-20 20 -100 100 -100 100 nA
1, 2, 3 -20 20 -100 100 -100 100 nA
1, 2, 3 -20 20 -100 100 -100 100 nA
1, 2, 3 -20 20 -100 100 -100 100 nA
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
4.5 7.0 4.5 7.0 4.5 7.0 V
-- 0.3 -- 0.3 -- 0.3 V
Vref
Vref
Vref
0.7 -- 0.7 -- 0.7 -- V
Vref
Vref
Vref
0.65 6.5 0.65 6.5 0.65 6.5 mA
-0.65 -6.5 -0.65 -6.5 -0.65 -6.5
0.65 6.5 0.65 6.5 0.65 6.5 mA
-0.65 6.5 -0.65 -6.5 -0.65 -6.5
1. Current limit set to 10 µ A during test.
06.17.02 REV 5 All data sheets are subject to change without notice 7
©2021 Maxwell Technologies
All rights reserved.