English
Language : 

81840 Datasheet, PDF (4/12 Pages) List of Unclassifed Manufacturers – 128 Channel Multiplexer
128 Channel Multiplexer
81840
TABLE 2. 81840 ABSOLUTE MAXIMUM RATINGS1,2,3,4
ENVIRONMENT
RANGES
V+ To Ground
V- To Ground
Input Overvoltage, AIN(1) to AIN(128)
Input Overvoltage, Logic Inputs
Power Dissipation
Storage Temperature
Operating Temperature
20V
-20V
35V to-35V
(Power ON or OFF)
4V over VREF and -4V below
Grd
500mW Maximum
-65 to 150°C
-55 to 125°C
1. The LMUX MCM is designed to operate with power supply voltages ranging
from ±5.2V to ±20VDC.
2. The maximum voltage each input AIN(128:1) may see without damage is
+35V to -35V with respect to ground.
3. Stresses above the absolute maximum rating may cause permanent damage
to the device. Extended operation at the maximum levels may degrade per-
formance and affect reliability.
4. TA = 25°C unless otherwise specified.
TABLE 3. 81840 AC ELECTRICAL CHARACTERISTICS
PARAMETER
TEST CONDITIONS SUBGROUPS
TEST LIMITS
TA = 25°C TA = 125°C
Address Input to I/O Channels
Prop. Delay
tON(A)
tOFF(A)
Enable to I/O
tON(EN)
tOFF(EN)
On Channel Isolation
VISO(ON)
Off Channel Isolation
VISO(OFF)
VIN = 5.0V
RL = 5k>
CL = 50pF
VIN = 5.0V
RL = 5k>
CL = 50 pF
All enable = 0.8V
VIN = 3VRMS @
500kHz1
All enable = 4.0V
VIN = 3VRMS @
500kHz1
MIN MAX MIN MAX
9, 10, 11
-- 1500 -- 1500
-- 1500 -- 1500
9, 10, 11
-- 1500 -- 1500
-- 1500 -- 1500
4, 5, 6
45 -- 45 --
4, 5, 6
45 -- 45 --
UNITS
TA = -55°C
MIN MAX
-- 1500 nsec
-- 1500
-- 1500 nsec
-- 1500
45 -- db
45 -- db
1. Controlled by design, not directly tested.
06.17.02 REV 5 All data sheets are subject to change without notice 4
©2021 Maxwell Technologies
All rights reserved.