English
Language : 

MAX14670 Datasheet, PDF (8/13 Pages) Maxim Integrated Products – Bidirectional Current-Blocking, High-Input Overvoltage Protector with Adjustable OVLO
MAX14670–MAX14673
Pin Configurations
Bidirectional Current-Blocking, High-Input
Overvoltage Protector
with Adjustable OVLO
TOP VIEW
(BUMPS ON BOTTOM)
1
+ OUT
A
OUT
B
IN
C
MAX14670
MAX14671
2
3
4
OUT
OUT
OUT
5
OTG_EN
IN
ACOK OVLO ACOK
IN
IN
IN
GND
WLP
IN IN IN GND ACOK
10 9 8 7 6
MAX14672
MAX14673
+
EP
1234 5
OUT OUT OVLO OTG_ ACOK
EN
TDFN-EP
*CONNECT EP TO GND
Pin Descriptions
BUMP
MAX14670/
MAX14671
PIN
MAX14672/
MAX14673
A1­–B1
1, 2
A5
4
B2, C1­–C4
8-10
B3
6
B4
3
B5
5
C5
7
—
—
NAME
FUNCTION
OUT
OTG_EN
IN
ACOK
OVLO
ACOK
GND
EP
Overvoltage Protection Output. Bypass OUT with a 1µF ceramic capacitor.
Externally connect all OUT together.
Enable Input for OTG Supply Operation
Overvoltage Protection Input. If desired, bypass IN with a 0.1µF ceramic capacitor
as close to the device as possible. Externally connect all IN together.
1.8V Logic Output. ACOK is driven high after input voltage is stable between
minimum VIN and VOVLO when OTG_EN = 0. Connect a pulldown resistor from
ACOK to ground.
Overvoltage Lockout Input. Connect OVLO to GND to use internal OVLO threshold.
Connect OVLO to a resistor-divider for a different voltage threshold.
Open-Drain Flag Output. ACOK is driven low after input voltage is stable between
minimum VIN and VOVLO when OTG_EN = 0. Connect a pullup resistor from
ACOK to the logic I/O voltage of the host system.
Ground
Exposed Pad (TDFN only) Connect EP to ground.
www.maximintegrated.com
Maxim Integrated │  8