English
Language : 

MAX14653 Datasheet, PDF (7/11 Pages) Maxim Integrated Products – High-Current Overvoltage Protector with Adjustable OVLO
MAX14653/MAX14654/
MAX14655
High-Current Overvoltage Protector
with Adjustable OVLO
Pin Configuration
TOP VIEW
(BUMPS ON BOTTOM)
MAX14653
MAX14654
MAX14655
1
2
3
4
+ GND
OUT
OUT
GND
A
ACOK OUT
IN
GND
B
OVLO
IN
C
IN
GND
WLP
(1.3mm x 1.86mm)
Pin Description
PIN
A1, A4, B4, C4
A2, A3, B2,
NAME
GND
OUT
B1
ACOK
B3, C2, C3
IN
C1
OVLO
FUNCTION
Ground. Connect GND pins together for proper operation.
Output Voltage. Output of internal switch. Connect OUT pins together for proper operation.
Open-Drain Flag Output. ACOK is driven low after input voltage is stable between minimum VIN
and VOVLO after debounce. Connect a pullup resistor from ACOK to the logic I/O voltage of the
host system. ACOK is high impedance after thermal shutdown.
Voltage Input. Bypass IN with a 0.1µF ceramic capacitor as close as possible to the device.
Connect IN pins together for proper operation.
External OVLO Adjustment. Connect OVLO to GND when using the internal threshold. Connect
a resistor-divider to OVLO to set a different OVLO threshold; this external resistor-divider is
completely independent of the internal threshold.
www.maximintegrated.com
Maxim Integrated │  7