English
Language : 

MAX14653 Datasheet, PDF (3/11 Pages) Maxim Integrated Products – High-Current Overvoltage Protector with Adjustable OVLO
MAX14653/MAX14654/
MAX14655
High-Current Overvoltage Protector
with Adjustable OVLO
Electrical Characteristics (continued)
(VIN = +2.5V to +28V, CIN = 0.1μF, TA = -40ºC to +85ºC, unless otherwise noted. Typical values are at VIN = +5.0V, IIN ≤ 3A, and
TA = +25ºC.) (Note 3)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
IN Leakage Voltage by OVLO
Thermal Shutdown
VIN_LEAK
VOVLO = 20V, VIN = unconnected,
ROVLO = 1MΩ
0.5
V
130
ºC
Thermal-Shutdown Hysteresis
20
ºC
DIGITAL SIGNALS (ACOK)
ACOK Output Low Voltage
VOL
VI/O = 3.3V, ISINK = 1mA
(See Typical Application Circuit)
0.4
V
ACOK Leakage Current
VACOK_LEAK
VI/O = 3.3V, ACOK deasserted
(See Typical Application Circuit)
-1
1
µA
TIMING CHARACTERISTICS (Figure 1)
Debounce Time
tDEB
Time from 2.5V < VIN < VIN_OVLO to
VOUT = 10% of VIN
15
ms
Soft-Start Time
tSS
VOUT = 10% of VIN to soft-start off
30
ms
Switch Turn-On Time
VIN = 5V, RL = 100Ω,
tON
CLOAD = 100µF; VOUT from 10%;
VIN to 90% VIN
2
ms
Switch Turn-Off Time
tOFF
VIN > VOVLO to VOUT = 80% of VIN;
RL = 100Ω, VIN rising at 2V/µs
2
µs
ESD PROTECTION
Human Body Model
All pins
±2
kV
IEC 61000-4-2 Contact
Discharge
IN pin
±8
kV
IEC 61000-4-2 Air Gap
Discharge
IN pin
±15
kV
Note 3: All specifications are 100% production tested at TA = +25ºC, unless otherwise noted. Specifications are over -40ºC to
+85ºC and are guaranteed by design.
www.maximintegrated.com
Maxim Integrated │  3