English
Language : 

MAX16122 Datasheet, PDF (6/16 Pages) Maxim Integrated Products – Dual Pushbutton Controllers in Tiny 6-Bump WLP Package
MAX16122–MAX16125
Bump Configurations
TOP VIEW
BUMP SIDE DOWN
MAX16122/MAX16123
1
2
+
A RESET
MR2
B
SEL
MR1
C
VCC
GND
WLP
Dual Pushbutton Controllers in
Tiny 6-Bump WLP Package
MAX16124/MAX16125
1
2
+
A RESET SRESET
B
SEL
MR
C
VCC
GND
WLP
Bump Description
BUMP
MAX16122/ MAX16124/
MAX16123 MAX16125
NAME
FUNCTION
Active-Low Reset Output. RESET is either an open-drain or a push-pull output (see the
Selector Guide). RESET asserts low when VCC drops below the selected threshold and
A1
A1
RESET
remains low for the VCC reset timeout period after VCC rises above the reset threshold.
The RESET one-shot asserts low for the reset timeout period when the manual reset
input is asserted longer than the setup delay. The open-drain output requires an external
pullup resistor.
—
A2
SRESET Soft Reset Output. SRESET is the debounced version of MR.
Setup Delay Select Input. Connect SEL to VCC, GND, or leave unconnected to select
B1
B1
SEL a desired setup delay (see Table 1a); or connect an external resistor between SEL and
GND to select a desired setup delay (E suffix only, see Tables 1a and 1b).
—
B2
MR
Manual Reset Input. Internal 50kΩ pullup to VCC. Pull MR low for the setup delay (tSU)
to one-shot pulse RESET for the reset timeout period.
www.maximintegrated.com
Maxim Integrated │  6