USB Current-Limited Switch
in Pin-Compatible Package
PIN
SO TDFN
1
6
2, 3 1, 3, 9
4
5
5
7
6, 7, 8
2, 4,
8, 10
—
—
NAME
GND
IN
EN
OC
OUT
EP
Pin Description
FUNCTION
Ground
Input. P-channel MOSFET source. Connect all IN pins together and bypass with a 1µF capacitor to
ground.
Active-Low Switch Enable Input. A logic-low turns on the switch.
Overcurrent Indicator Output. This open-drain output goes low when the device is in thermal
shutdown or undervoltage lockout, or during a sustained (> 10ms) current-limit condition.
Switch Output. P-channel MOSFET drain. Connect all OUT pins together and bypass with a 0.1µF
capacitor to ground.
Exposed Paddle (TDFN Package Only). Internally connected to GND. Connect to a large ground
plane to maximize thermal performance. Not intended as an electrical connection point.
IN
OC
N
EN
P
OUT
MAX1607
P
REPLICA
AMPLIFIER
ON
P
ON
10ms
TIMER
HOT
CURRENT-LIMIT
AMPLIFIER
1.24V
GND
CONTROL
CIRCUITRY
Figure 1. Functional Diagram
Detailed Description
The MAX1607 P-channel MOSFET power switch limits
output current to 0.7A min and 1.0A max. When the out-
put current is increased beyond the current limit (ILIMIT),
the current also increases through the replica switch
(IOUT / 6500). The current-limit error amplifier compares
the voltage to the internal 1.24V reference and regu-
lates the current back to the ILIMIT (Figure 1).
These switches are not bidirectional; therefore, the
input voltage must be higher than the output voltage.
Continuous Short-Circuit Protection
The MAX1607 is a short-circuit-protected switch. In the
event of an output short-circuit condition, the current
through the switch is foldback-current-limited to 500mA
continuous.
Thermal Shutdown
The MAX1607 has a thermal shutdown feature. The
switch turns off and the OC output goes low immediate-
ly (no overcurrent blanking) when the junction tempera-
ture exceeds +165°C. When the MAX1607 cools 20°C,
the switch turns back on. If the fault short-circuit condi-
tion is not removed, the switch will cycle on and off,
resulting in a pulsed output.
OC Indicator
The MAX1607 provides an overcurrent output (OC). A
100kΩ pull-up resistor from OC to IN provides a logic
control signal. This open-drain output goes low when
any of the following conditions occur:
• The input voltage is below the 2.4V undervoltage-
lockout (UVLO) threshold.
• The die temperature exceeds the thermal shutdown
temperature limit of +165°C.
• The device is in current limit for greater than 10ms.
OC Blanking
The MAX1607 features 10ms overcurrent blanking.
Blanking allows brief current-limit faults, including
momentary short-circuit faults that occur when hot-
swapping a capacitive load, and also ensures that no
OC is issued during power-up. When a load transient
causes the device to enter current limit, an internal
6 _______________________________________________________________________________________