+5.0V, ±15kV ESD-Protected, Fail-Safe,
Hot-Swap, RS-485/RS-422 Transceivers
DRIVER SWITCHING CHARACTERISTICS
MAX13086E/MAX13087E/MAX13088E/MAX13089E WITH SRL = GND (16Mbps)
(VCC = +5.0V ±10%, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5.0V and TA = +25°C.)
PARAMETER
Driver Propagation Delay
Driver Differential Output Rise or
Fall Time
SYMBOL
tDPLH
tDPHL
CONDITIONS
CL = 50pF, RL= 54Ω, Figures 2 and 3
tR , tF CL = 50pF, RL= 54Ω, Figures 2 and 3
MIN TYP MAX
50
50
15
Differential Driver Output Skew
|tDPLH - tDPHL|
tDSKEW CL = 50pF, RL= 54Ω, Figures 2 and 3
Maximum Data Rate
16
Driver Enable to Output High
tDZH Figure 4
Driver Enable to Output Low
tDZL Figure 5
Driver Disable Time from Low
tDLZ Figure 5
Driver Disable Time from High
tDHZ Figure 4
Driver Enable from Shutdown to
Output High
tDZH(SHDN) Figure 4
8
150
150
100
100
2200
Driver Enable from Shutdown to
Output Low
tDZL(SHDN) Figure 5
2200
Time to Shutdown
tSHDN
50
340
700
UNITS
ns
ns
ns
Mbps
ns
ns
ns
ns
ns
ns
ns
RECEIVER SWITCHING CHARACTERISTICS
MAX13086E/MAX13087E/MAX13088E/MAX13089E WITH SRL = GND (16Mbps)
(VCC = +5.0V ±10%, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5.0V and TA = +25°C.)
PARAMETER
Receiver Propagation Delay
Receiver Output Skew
|tRPLH - tRPHL|
Maximum Data Rate
Receiver Enable to Output Low
Receiver Enable to Output High
Receiver Disable Time from Low
Receiver Disable Time from High
Receiver Enable from Shutdown
to Output High
SYMBOL
tRPLH
tRPHL
CONDITIONS
CL = 15pF, Figures 6 and 7
tRSKEW CL = 15pF, Figures 6 and 7
tRZL
tRZH
tRLZ
tRHZ
Figure 8
Figure 8
Figure 8
Figure 8
tRZH(SHDN) Figure 8
MIN TYP MAX UNITS
50
80
ns
50
80
13
ns
16
Mbps
50
ns
50
ns
50
ns
50
ns
2200
ns
Receiver Enable from Shutdown
to Output Low
tRZL(SHDN) Figure 8
2200
ns
Time to Shutdown
tSHDN
50
340
700
ns
Note 1: All currents into the device are positive. All currents out of the device are negative. All voltages are referred to device ground,
unless otherwise noted.
Note 2: ∆VOD and ∆VOC are the changes in VOD and VOC, respectively, when the DI input changes state.
Note 3: The short-circuit output current applies to peak current just prior to foldback current limiting. The short-circuit foldback output
current applies during current limiting to allow a recovery from bus contention.
6 _______________________________________________________________________________________