English
Language : 

MAX13020_12 Datasheet, PDF (6/16 Pages) Maxim Integrated Products – ±60V Fault-Protected LIN Transceivers
MAX13020/MAX13021
±60V Fault-Protected LIN Transceivers
TIMING CHARACTERISTICS (continued)
(VBAT = +5V to +38V, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VBAT = +12V and TA = +25°C. Positive
currents flow into the device.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Mode Change Time from
Sleep/Standby Mode to
Normal/Low Slope Mode
tGOTONORM (Note 3)
2
5
10
µs
Mode Change Time from
Normal/Low Slope Mode to Sleep
Mode
tGOTOSLEEP (Note 4)
2
5
10
µs
Note 1: Guaranteed by design for VBAT = VLIN = +27V.
Note 2: Selected bit time, tBIT = 50µs or 96µs (20kbaud or 10.4kbaud). Bus load conditions (CBUS / RBUS): 1nF/1kΩ, 6.8nF/660Ω,
10nF/500Ω.
Note 3: tGOTONORM is measured from rising edge of NSLP to RXD active.
Note 4: tGOTOSLEEP is measured from falling edge of NSLP to RXD high impedance.
(VBAT = +12V and TA = +25°C, unless otherwise noted.)
Typical Operating Characteristics
SUPPLY CURRENT
vs. TEMPERATURE
10
SLEEP MODE
9
VLIN = VBAT
8
7
6
5
4
VBAT = +38V
3
VBAT = +12V
2
1
0
-40 -25 -10 5 20 35 50 65 80 95 110 125
TEMPERATURE (°C)
OPERATING CURRENT
vs. SUPPLY VOLTAGE
50
RL = 500Ω
45
NORMAL SLOPE MODE CL = 10nF
40
20kbps
35
30
25
20
15
RL = 1000Ω
CL = 1nF
10
5
LOW SLOPE MODE
10.4kbps
0
5 10 15 20 25 30 35 40
SUPPLY VOLTAGE (V)
SINK CURRENT vs. RXD OUTPUT
LOW VOLTAGE
30
25
TA = -40°C
20
TA = +25°C
15
TA = +125°C
10
5
0
0
1
2
3
4
5
RXD OUTPUT LOW VOLTAGE (V)
6
Maxim Integrated