English
Language : 

MAX13020_12 Datasheet, PDF (5/16 Pages) Maxim Integrated Products – ±60V Fault-Protected LIN Transceivers
MAX13020/MAX13021
±60V Fault-Protected LIN Transceivers
TIMING CHARACTERISTICS
(VBAT = +5V to +38V, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VBAT = +12V and TA = +25°C. Positive
currents flow into the device.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
VBAT = +7V to +18V, Vth(REC)(MAX) =
LIN Duty Factor 1
D1 = tBUS(REC)(MAX)/(2 x tBIT)
D1
0.744 x VBAT,
Vth(DOM)(MAX) = 0.581 x VBAT,
0.396
—
tBIT = 50µs (Figure 4, Note 2)
LIN Duty Factor 2
D2 = tBUS(REC)(MAX)/(2 x tBIT)
VBAT = +8V to +18V,
D2
Vth(REC)(MIN) = 0.422 x VBAT,
Vth(DOM)(MIN) = 0.284 x VBAT,
tBIT = 50µs (Figure 4, Note 2)
0.581
—
VBAT = +7V to +18V,
LIN Duty Factor 3
D3 = tBUS(REC)(MAX)/(2 x tBIT)
D3
Vth(REC)(MAX) = 0.778 x VBAT,
Vth(DOM)(MAX) = 0.616 x VBAT,
0.417
—
tBIT = 96µs (Figure 4, Note 2)
LIN Duty Factor 4
D4 = tBUS(REC)(MAX)/(2 x tBIT)
Vth(REC)(MIN) = 0.389 x VBAT,
D4
Vth(DOM)(MIN) = 0.251 x VBAT,
VBAT = +8V to +18V,
tBIT = 96µs (Figure 4, Note 2)
0.590
—
Propagation Delay of Receiving
Node
tp(RX)
VBAT = +7V to +18V,
CRXD = 20pF (Figure 4)
6
µs
Receiver Propagation Delay
Symmetry
Rising edge with respect to falling edge,
tp(RX)(SYM) VBAT = +7V to +18V,
-2
CRXD = 20pF, RRXD = 1kΩ
+2
µs
Continuously Dominant-Clamped
LIN Bus Detection Time
tLIN(DOM)(DET)
Normal/low slope mode (MAX13021),
VLIN = VGND
40
80
160
ms
Continuously Dominant-Clamped
LIN Bus Recovery Time
tLIN(DOM)(REC)
Normal/low slope mode (MAX13021),
VLIN = VGND
0.5
1
2
ms
Dominant Time for Wake-Up of
the LIN Transceiver
tBUS
Sleep mode (Figure 3)
30
70
150
µs
TXD Permanent Dominant
Disable Time
tTXD(DOM)(DIS)
Normal/low slope mode,
VTXD = VGND
20
80
ms
Dominant Time for Wake-Up
Through NWAKE
tNWAKE
Sleep mode
7
20
50
µs
Maxim Integrated
5