English
Language : 

MAX1693 Datasheet, PDF (5/8 Pages) Maxim Integrated Products – USB Current-Limited Switches with Fault Blanking
USB Current-Limited Switches
with Fault Blanking
Typical Operating Characteristics (continued)
(VIN = +5V, TA = +25°C, unless otherwise noted.)
MAX1693
CURRENT-LIMIT AND FAULT RESPONSE
MAX1693
CURRENT-LIMIT RESPONSE
1
1
2
2
3
3
4
2ms/div
CH1 = VIN, 200mV/div, AC-COUPLED; CH2 = VOUT,
5V/div; CH3 = VFAULT, 5V/div; CH4 = IOUT, 500mA/div
MAX1693
SWITCH TURN-ON TIME
4
10µs/div
CH1 = VIN, 200mV/div, AC-COUPLED; CH2 = VOUT,
5V/div; CH3 = VFAULT, 5V/div; CH4 = IOUT, 1A/div
MAX1693
SWITCH TURN-OFF TIME
1
1
2
2
3
3
4
4
20µs/div
CH1 = VOUT, 5V/div; CH2 = VON, 5V/div;
CH3 = VFAULT, 5V/div; CH4 = IOUT, 200mA/div
MAX1694
OVERCURRENT TO FAULT
AND SWITCH LATCHED OFF
1µs/div
CH1 = VOUT, 5V/div; CH2 = VON, 5V/div;
CH3 = VFAULT, 5V/div; CH4 = IOUT, 200mA/div
MAX1693
START-UP TIME
(TYPICAL USB APPLICATION)
1
1
CL = 150µF
RL = 15Ω
2
2
FULL-CURRENT LIMIT CHARGES CAPACITOR
3
FOLDBACK-
CURRENT LIMIT
RESISTOR
LOAD
CURRENT
3
4
2ms/div
1ms/div
CH1 = VFAULT, 5V/div; CH2 = IOUT, 5V/div;
CH3 = IOUT, 1A/div
CH1 = VOUT, 5V/div; CH2 = VON, 5V/div;
CH3 = IOUT, 500mA/div; CH4 = VFAULT, 5V/div
_______________________________________________________________________________________ 5