English
Language : 

MAX1693 Datasheet, PDF (3/8 Pages) Maxim Integrated Products – USB Current-Limited Switches with Fault Blanking
USB Current-Limited Switches
with Fault Blanking
ELECTRICAL CHARACTERISTICS
(VIN = +5V, TA = -40°C to +85°C, unless otherwise noted.) (Note 3)
PARAMETER
Operating Voltage
Quiescent Current
Off-Supply Current
Undervoltage Lockout
SYMBOL
VIN
IQ
UVLO
CONDITIONS
V ON = GND, IOUT = 0, timer not running
V ON = VIN = VOUT = 5.5V
Rising edge, 100mV hysteresis
MIN TYP MAX UNITS
3
5.5
V
25
µA
2
µA
2.0
2.9
V
Off-Switch Leakage
V ON = VIN = 5.5V, VOUT = GND
15
µA
On-Resistance
Current Limit
Continuous Short-Circuit
Current Limit
ON Input Logic Low Voltage
ON Input Logic High Voltage
ON Input Leakage
FAULT Output Logic Low
Voltage
FAULT Output High Leakage
Current
Fault-Blanking Timeout Period
Switch Turn-On Time
Switch Turn-Off Time
RON
VIN = 4.4V to 5.5V
VIN = 3V
ILIMIT (Note 1)
640
OUT shorted to GND, MAX1693 only (Note 2)
VIL
VIN = 3V to 5.5V
VIH
VIN = 3V to 3.6V
2
VIN = 3.7V to 5.5V
2.4
VON = VIN or GND
VOL
ISINK = 1mA, VIN = 3V
VIN = VFAULT = 5.5V
tFB
From overcurrent condition to FAULT assertion 6
tON
ILOAD = 400mA
tOFF ILOAD = 400mA
1
125
mΩ
150
1060 mA
750
mA
0.8
V
V
±1
µA
0.4
V
1
µA
14
ms
200
µs
20
µs
Note 1: MAX1693’s current limit is tested by forcing VOUT to 4.5V. The MAX1694’s current limit is tested by increasing the output cur-
rent until the switch is latched off.
Note 2: This specification applies to the MAX1693 only. The MAX1694 latches the switch off under a sustained (>10ms) short-
circuit condition.
Note 3: Specifications to -40°C are guaranteed by design, not production tested.
_______________________________________________________________________________________ 3