English
Language : 

MAX16016_0812 Datasheet, PDF (5/21 Pages) Maxim Integrated Products – Low-Power μP Supervisory Circuits with Battery-Backup Circuit and Chip-Enable Gating
Low-Power µP Supervisory Circuits with
Battery-Backup Circuit and Chip-Enable Gating
ELECTRICAL CHARACTERISTICS (continued)
(VCC = 1.53V to 5.5V, VBATT = 3V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.) (Note 2)
PARAMETER
LOW LINE (LL)
SYMBOL
CONDITIONS
MIN
TYP
MAX UNITS
Low Line to Reset Threshold
Voltage
VCC falling
VCC Falling to LL Delay
LL Output Low Voltage
LL Output High Voltage (Push-
Pull Output)
VCC falling at 10V/ms
VOL
VCC ≥ 1.6V, ISINK = 1mA, LL asserted
VCC ≥ 1.2V, ISINK = 100µA, LL asserted
VOH
VCC = 0.9 x VTH_LL, ISOURCE = 100µA,
LL deasserted
Output Leakage Current
VLL = 5.5V, LL deasserted
BATTERY-OK INDICATOR (BATTOK, BATT_TEST)
BATTOK Threshold
Inferred internally from BATT
BATTOK Output Voltage Low
VOL
VCC = 1.1 x VTH, ISINK = 1mA, reset
asserted
BATTOK Output High Voltage
VOH
VCC = 1.1 x VTH, ISOURCE = 100µA,
BATTOK asserted
(see Table 2)
mV
20
VOUT -
0.3
µs
0.3
V
0.3
V
1
µA
2.508
2.6
2.673
V
0.3
V
VOUT -
0.3
V
BATTOK Output Leakage
Current
VBATTOK = 5.5V, deasserted
1
µA
BATT_TEST Output Low Voltage
VCC = 1.1 x VTH, ISINK = 1mA
0.3
V
Note 2: All devices are 100% production tested at TA = +25°C and TA = +85°C. Limits to -40°C are guaranteed by design.
Note 3: VBATT can be 0V anytime, or VCC can go down to 0V if VBATT is active (except at startup).
Note 4: Use external current-limit resistor to limit current to 20mA (max).
Note 5: CEIN/CEOUT resistance is tested with VCC = 5V and VCEIN = 0V or 5V.
Note 6: WDI is internally serviced within the watchdog period if WDI is left unconnected.
Note 7: The WDI input current is specified as the average input current when the WDI input is driven high or low. The WDI input is
designed for a three-stated output device with a 10µA maximum leakage current and capable of driving a maximum capaci-
tive load of 200pF. The three-state device must be able to source and sink at least 200µA when active.
Table 1a. Reset Threshold Ranges
(MAX16016)
SUFFIX
L
M
T
S
R
Z
Y
W
V
RESET THRESHOLD RANGES (V)
MIN
TYP
MAX
4.508
4.63
4.906
4.264
4.38
4.635
2.991
3.08
3.239
2.845
2.93
3.080
2.549
2.63
2.755
2.243
2.32
2.425
2.117
2.19
2.288
1.603
1.67
1.733
1.514
1.575
1.639
Table 1b. Reset Threshold Ranges
(MAX16020/MAX16021)
SUFFIX
L
M
T
S
R
Z
Y
W
V
RESET THRESHOLD RANGES (V)
MIN
TYP
MAX
4.520
4.684
4.852
4.275
4.428
4.585
3.010
3.100
3.190
2.862
2.946
3.034
2.568
2.640
2.716
2.260
2.323
2.390
2.133
2.192
2.255
1.616
1.661
1.710
1.528
1.571
1.618
_______________________________________________________________________________________ 5