English
Language : 

MAX14781E_14 Datasheet, PDF (5/19 Pages) Maxim Integrated Products – Half-Duplex RS-485 Transceiver with Polarity Correction
MAX14781E
Half-Duplex RS-485 Transceiver
with Polarity Correction
Switching Characteristics (continued)
(VCC = 5V ± 10%, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VCC = 5V and TA = +25°C.)(Notes 2, 3)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
Receiver Enable to Output Low
tRZL
RL = 1kΩ, CL = 15pF, Figure 8
(Note 9)
50
ns
Receiver Disable Time from Low
tRLZ
RL = 1kΩ, CL = 15pF, Figure 8
(Note 9)
50
ns
Receiver Disable Time from High
tRHZ
RL = 1kΩ, CL = 15pF, Figure 8
(Note 9)
50
ns
Receiver Enable from Shutdown
to Output High
tRZH(SHDN)
RL = 1kΩ, CL = 15pF, Figure 8
(Note 9)
5.5
μs
Receiver Enable from Shutdown
to Output Low
tRZL(SHDN)
RL = 1kΩ, CL = 15pF, Figure 8
(Note 9)
5.5
μs
Time to Shutdown
tSHDN
(Note 10)
50
340
700
ns
Note 2: All devices are 100% production tested at TA = +25°C. Spefications over temperature are guaranteed by design.
Note 3: All currents into the device are positive. All currents out of the device are negative. All voltages are referenced to ground,
unless otherwise noted.
Note 4: ΔVOD and ΔVOC are the changes in VOD and VOC, respectively, when the DI input changes state.
Note 5: The short-circuit output current applies to the peak current just prior to foldback current limiting. The short-circuit foldback
output current applies during current limiting to allow recovery from a bus contention.
Note 6: tPM is the interval, with no A/B switching activity, after which the internal logic circuitry records the polarity. tPM includes the
correction delay, after which the polarity is changed.
Note 7: Not production tested. Guaranteed by design.
Note 8: Capacitive loads include test probe and fixture capacitance.
Note 9: This parameter refers to the driver/receiver enable delay when the device has exited the initial hot-swap state and is in nor-
mal operating mode.
Note 10: Shutdown is enabled by driving RE high and DE low. The device is guaranteed to have entered shutdown after tSHDN has
elapsed.
www.maximintegrated.com
Maxim Integrated │  5