English
Language : 

MAX13050ASA Datasheet, PDF (5/20 Pages) Maxim Integrated Products – Industry-Standard High-Speed CAN Transceivers with +80,-80V Fault Protection
MAX13050/MAX13052/MAX13053/MAX13054
Industry-Standard High-Speed CAN
Transceivers with ±80V Fault Protection
TIMING CHARACTERISTICS (continued)
(VCC = +5V ±5%, VCC2 = +3V to +3.6V, RL = 60Ω, CL = 100pF, TA = TMIN to TMAX, unless otherwise noted. Typical values are at
VCC = +5V, VCC2 = +3.3V, and TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Dominant Time for Wake-Up with
Bus
tWAKE Standby mode, VDIFF = +3V, Figure 2
0.75
1.5
3.00
µs
Delay STBY to Normal Mode
(DOMINANT)
TXD Dominant Timeout
tSTBY- TXD = 0 (MAX13050, MAX13054)
5
NORM FROM STBY falling to CANH - CANL = 0.9V
10
µs
tDOM
VTXD = 0
0.3
0.6
1.0
ms
Note 1: All currents into the device are positive, all currents out of the device are negative. All voltages are referenced to the device
ground, unless otherwise noted.
Note 2: Guaranteed by design, not production tested.
Note 3: MAX13050 tested by IBEE test facility. Please contact factory for report. MAX13052/MAX13053/MAX13054 are pending ESD
evaluation.
Note 4: For the MAX13052, VRS = 0.
Timing Diagrams
TXD
DOMINANT
0.9V
VDIFF
RXD
0.3 x VCC OR 0.3 x VCC2
tONTXD
tONRXD
tONLOOP
Figure 1. Timing Diagram
Maxim Integrated
0.5V
RECESSIVE
0.7 x VCC OR 0.7 x VCC2
tOFFTXD
tOFFRXD
tOFFLOOP
5