English
Language : 

MAX13050ASA Datasheet, PDF (4/20 Pages) Maxim Integrated Products – Industry-Standard High-Speed CAN Transceivers with +80,-80V Fault Protection
MAX13050/MAX13052/MAX13053/MAX13054
Industry-Standard High-Speed CAN
Transceivers with ±80V Fault Protection
DC ELECTRICAL CHARACTERISTICS (continued)
(VCC = +5V ±5%, VCC2 = +3V to +3.6V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V, VCC2 = +3.3V,
RL = 60Ω, and TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Input Voltage for Standby
VIH_RS
0.75 x
V
VCC
Slope-Control Mode Voltage
VSLOPE -200µA < IRS < 10µA
0.4 x
VCC
0.6 x
VCC
V
High-Speed Mode Current
IIL_RS VRS = 0
-500
µA
ESD Protection
IEC 61000-4-2 Contact Discharge Method
±8
kV
per IBEE test facility (Note 3)
TIMING CHARACTERISTICS
(VCC = +5V ±5%, VCC2 = +3V to +3.6V, RL = 60Ω, CL = 100pF, TA = TMIN to TMAX, unless otherwise noted. Typical values are at
VCC = +5V, VCC2 = +3.3V, and TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Delay TXD to Bus Active
tONTXD Figure 1 (Note 4)
66
110
ns
Delay TXD to Bus Inactive
tOFFTXD
Figure 1
(Note 4)
MAX13050/MAX13052/
MAX13053
MAX13054
61
95
ns
70
110
Delay Bus to Receiver Active
Delay Bus to Receiver Inactive
tONRXD Figure 1 (Note 4)
tOFFRXD Figure 1 (Note 4)
54
115
ns
46
160
ns
Delay TXD to RXD Active
(Dominant Loop Delay)
tONLOOP Figure 1 (Note 4)
121 255
ns
Delay TXD to RXD Inactive
(Recessive Loop Delay)
tOFFLOOP Figure 4 (Note 4)
108 255
ns
Delay TXD to RXD Active
(Dominant Loop Delay) Slew-Rate
Controlled
tONLOOP-S MAX13052
RRS = 24kΩ
(500kbps)
RRS = 100kΩ
(125kbps)
RRS = 180kΩ
(62.5kbps)
280 450
ns
0.82 1.6
µs
1.37
5
RRS = 24kΩ
(500kbps)
386 600
ns
Delay TXD to RXD Inactive (Loop
Delay) Slew-Rate Controlled
tOFFLOOP-S MAX13052
RRS = 100kΩ
(125kbps)
RRS = 180kΩ
(62.5kbps)
0.74 1.6
µs
0.97
5
RRS = 24kΩ
10
(500kbps)
Differential Output Slew Rate
|SR| MAX13052
RRS = 100kΩ
(125kbps)
2.7
V/µs
RRS = 180kΩ
1.6
(62.5kbps)
4
Maxim Integrated