English
Language : 

MAX1253 Datasheet, PDF (5/29 Pages) Maxim Integrated Products – Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Stand-Alone, 10-Channel, 12-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
TIMING CHARACTERISTICS
(VDD = +2.7V to +3.6V (MAX1253), VDD = +4.5V to +5.5V (MAX1254), TA = TMIN to TMAX, unless otherwise noted.) (Figures 1, 2, and 4)
PARAMETER
SCLK Clock Period
SCLK Pulse Width High Time
SCLK Pulse Width Low Time
DIN to SCLK Setup Time
DIN to SCLK Hold Time
CS Fall to SCLK Rise Setup
SCLK Rise to CS Rise Hold
SCLK Fall to DOUT Valid
CS Rise to DOUT Disable
CS Fall to DOUT Enable
CS Pulse Width High
SYMBOL
tCP
tCH
tCL
tDS
tDH
tCSS
tCSH
tDOV CL = 30pF
tDOD CL = 30pF
tDOE CL = 30pF
tCSW
CONDITIONS
MIN TYP MAX UNITS
100 0.5
ns
45
ns
45
ns
25
ns
0
ns
25
ns
50
ns
50
ns
40
ns
40
ns
40
ns
Note 1: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain and offset errors
have been calibrated.
Note 2: Offset nulled.
Note 3: In reference mode 00, the reference system powers up for each temperature measurement. In reference mode 01, the ref-
erence system powers up once per sequence of channels scanned. If a sample wait <80µs is programmed, the reference
system is on all the time. In reference mode 10, the reference system is on all the time (see Table 7).
Note 4: No external capacitor on REF.
Note 5: The operational input voltage range for each individual input of a differentially configured pair (AIN0–AIN7) is from GND to
VDD. The operational input voltage difference is from -VREF/2 to +VREF/2.
Note 6: See Figure 3 and the Sampling Error vs. Input Source Impedance graph in the Typical Operating Characteristics section.
Note 7: Grade A tested at +10°C and +55°C. -20°C to +85°C and -40°C to +85°C specifications guaranteed by design. Grade B
tested at +25°C. TMIN to TMAX specification guaranteed by design.
Note 8: External temperature measurement mode using an MMBT3904 (Diodes Inc.) as a sensor. External temperature sensing
from -40°C to +85°C; MAX1253/MAX1254 held at +25°C.
Note 9: Performing eight single-ended external channels’ temperature measurements, an internal temperature measurement, and
an internal VDD measurement with no sample wait results in a conversion rate of 2ksps per channel.
Note 10: Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD measure-
ment with no sample wait results in a conversion rate of 7ksps per channel.
Note 11: Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD measure-
ment with maximum sample wait results in a conversion rate of 3ksps per channel.
Note 12: Defined as the shift in the code boundary as a result of supply voltage change. VDD = min to max; full-scale input, mea-
sured using external reference.
_______________________________________________________________________________________ 5