ELECTRICAL CHARACTERISTICS (continued)
(VPV1 = 13.5V, VPV2 = VPV3 = VOUT1, VPV4 = VOUT2; TA = TJ = -40°C to +125°C, unless otherwise noted. Typical values are at
TA = +25°C under normal conditions, unless otherwise noted.) (Note 2)
PARAMETER
RESET
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
OUT1 OV Threshold
110
%
OUT1 Reset Threshold
OUT2 Reset Threshold
Reset option 1 (see the Selector Guide)
Reset option 2 (see the Selector Guide)
Percentage of nominal output
85
90
95
%
75
80
85
85
90
95
%
Reset Timeout Period
Output-High Leakage Current
Output Low Level
UV Propagation Time
EN LOGIC INPUT
EN Threshold Voltage
EN Threshold Hysteresis
Input Current
PWM LOGIC INPUT
Input High Level
Input Low Level
Logic-Input Current
Reset timeout option 1 (see the Selector
Guide)
Reset timeout option 2 (see the Selector
Guide)
Sinking -3mA
EN rising
VEN = 5V
PWM rising
PWM falling
0 ≤ VPWM ≤ 5.5V
14.9
ms
1.9
1
µA
0.4
V
28
µs
1.4
1.8
2.2
V
0.4
V
0.5
µA
1.8
V
0.4
V
1
µA
Note 2: All units are 100% production tested at TA = +25°C. All temperature limits are guaranteed by design.
Note 3: Once PVI exceeds undervoltage-lockout rising threshold 4.0V and the device is in regulation.
Note 4: Guaranteed by design. Not product tested.
4 _______________________________________________________________________________________