English
Language : 

MAX1610 Datasheet, PDF (4/20 Pages) Maxim Integrated Products – Digitally Controlled CCFL Backlight Power Supplies
Digitally Controlled CCFL Backlight
Power Supplies
TIMING CHARACTERISTICS—MAX1610
(Figure 1, TA = +25°C, unless otherwise noted.)
PARAMETER
SYMBOL
UP, DN Pulse Width High
t1
UP, DN Pulse Width Low
t2
UP, DN Pulse Separation
t3
Counter Reset Time
t4
CONDITIONS
MIN TYP MAX UNITS
1
µs
1
µs
1
µs
1
µs
TIMING CHARACTERISTICS—MAX1611
(Figures 2 and 3, TA = +25°C, unless otherwise noted.)
PARAMETER
SYMBOL
SCL Serial Clock High Period
tHIGH
SCL Serial Clock Low Period
tLOW
SCL, SCA Rise Time
tR
SCL, SDA Fall Time
tF
Start Condition Setup Time
tSU:STA
Start Condition Hold Time
tHD:STA
SDA Valid to SCL Rising Edge
Setup Time, Slave Clocking in Data
tSU:DAT
(Note 1)
(Note 1)
SCL Falling Edge to SDA
Transition
tHD:DAT (Note 1)
SCL Falling Edge to SDA Valid,
Reading Out Data
tDV
CONDITIONS
Note 1: Guaranteed by design.
MIN TYP MAX UNITS
4
µs
4.7
µs
1
µs
0.3
µs
4.7
µs
4
µs
500
ns
0
ns
1
µs
4 _______________________________________________________________________________________