MAX14691 Datasheet, PDF (4/19 Pages) Maxim Integrated Products – High-Accuracy, Adjustable Power Limiter
MAX14691–MAX14693
High-Accuracy, Adjustable Power Limiter
Electrical Characteristics (continued)
(VIN = 5.5V to 58V, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VIN = 12V, TA = +25°C) (Note 4)
SETI
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP MAX UNITS
RSETI x ILIM
VRI
Current Mirror Output Ratio
CIRATIO
DYNAMIC PERFORMANCE (Note 6)
See the Setting the Current-Limit
Threshold section
1.5
V
25000
Switch Turn-On Time
VIN = 24V, switch OFF to ON, RLOAD
tON
= 240Ω, ILIM = 1A, COUT = 4.7µF,
68
µs
VOUT from 20% to 80% of VIN
OVP Switch Response Time
tOVP_RES
3
µs
Overcurrent Switch Response
Time
tOCP_RES ILIM = 4A
3
µs
Startup Timeout
tSTO
Initial start current-limit foldback
timeout (Figure 1)
1090
1200 1320
ms
Startup Initial Time
tSTI
Current is continuously limited to
1x/1.5x/2x in this interval (Figure 1)
21.8
24
26.4
ms
IN Debounce Time
Blanking Time
Autoretry Time
THERMAL PROTECTION
Thermal Foldback
Thermal Shutdown
Thermal Shutdown Hysteresis
tDEB
tBLANK
tRETRY
Interval between VIN > VUVLO and
VOUT = 10% of VIN (Figure 2)
(Figures 3 and 4)
(Figure 3, Note 7)
TJ_FB
TJ_MAX
1
1.5
2.1
ms
21.8
24
26.4
ms
554
720
792
ms
150
ºC
165
ºC
10
ºC
Note 4: All devices are 100% production-tested at TA = +25ºC. Specifications over the operating temperature range are guaranteed
by design.
Note 5: Not production-tested, user-adjustable. See the Overvoltage Lockout (OVLO) and Undervoltage Lockout (UVLO) sections.
Note 6: All timing is measured using 20% and 80% levels, unless otherwise specified.
Note 7: The autoretry time-to-blanking time ratio is fixed and is equal to 30.
www.maximintegrated.com
Maxim Integrated │  4