English
Language : 

MAX13000E Datasheet, PDF (4/25 Pages) Maxim Integrated Products – Ultra-Low-Voltage Level Translators Enable/Shutdown Control
Ultra-Low-Voltage Level Translators
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +1.5V to +3.6V, VL = +0.9V to VCC, CI/OVL ≤ 15pF, CI/OVCC ≤ 50pF, TA = -40°C to +85°C, unless otherwise noted. Typical val-
ues are at TA = +25°C.) (Notes 1, 4)
PARAMETER
Output Source Current During
Transient (VCC Side)
Output Source Current During
Transient (VL Side)
ESD PROTECTION
I/OVCC_
SYMBOL
CONDITIONS
VCC = +1.65V,
MAX13003E/MAX13004E/MAX13005E
VCC = +1.65V,
MAX13000E/MAX13001E/MAX13002E
VL = +1.2V, VCC = +1.65V,
MAX13003E/MAX13004E/MAX13005E
VL = +1.2V, VCC = +1.65V,
MAX13000E/MAX13001E/MAX13002E
Human Body Model
Air-Gap Discharge (IEC61000-4-2)
Contact Discharge (IEC61000-4-2)
MIN
TYP MAX UNITS
22
mA
1
25
mA
1
±15
±10
kV
±8
TIMING CHARACTERISTICS
(VCC = +1.5V to +3.6V, VL = +0.9V to VCC, CI/OVL ≤ 15pF, CI/OVCC ≤ 50pF, TA = -40°C to +85°C, unless otherwise noted. Typical val-
ues are at TA = +25°C.) (Notes 1, 4)
PARAMETER
SYMBOL
CONDITIONS
CI/OVCC = 50pF,
MAX13003E/MAX13004E/MAX13005E,
VCC = +1.65V, Figures 1a, 1b
MIN TYP MAX UNITS
15
I/OVCC_ Rise Time
tRVCC
CI/OVCC = 50pF,
MAX13003E/MAX13004E/MAX13005E,
VCC = +1.5V, Figures 1a, 1b
15
ns
CI/OVCC = 50pF,
MAX13000E/MAX13001E/MAX13002E,
400
Figures 1a, 1b
1400
CI/OVCC = 50pF,
MAX13003E/MAX13004E/MAX13005E,
15
VCC = +1.65V, Figures 1a, 1b
I/OVCC_ Fall Time
tFVCC
CI/OVCC = 50pF,
MAX13003E/MAX13004E/MAX13005E,
VCC = +1.5V, Figures 1a, 1b
15
ns
CI/OVCC = 50pF,
MAX13000E/MAX13001E/MAX13002E,
400
Figures 1a, 1b
1400
4 _______________________________________________________________________________________