English
Language : 

MAX14890E Datasheet, PDF (3/30 Pages) Maxim Integrated Products – Overvoltage and Undervoltage Fault Detection
MAX14890E
Incremental Encoder Interface for RS-422,
HTL, and TTL with Digital Inputs
Electrical Characteristics (continued)
(VCC = 5V±10%, VL = 1.62V to VCC, TA = -40°C to +125°C unless otherwise noted. Typical values are at VCC = 5V, VL = 3.3V,
TA = +25°C.) (Notes 2, 3 )
PARAMETER
SYMBOL
CONDITIONS
Low Differential Voltage Fault
VTH_DFP 0V ≤ VCM ≤ +24V, Positive
Threshold
Single-Ended Input Fault
Threshold
VTH_DFN
VTH_SEN
0V ≤ VCM ≤ +24V, Negative
Negative
SINGLE-ENDED HTL RECEIVERS (RxA, RxB, RxZ)
Input Logic High Voltage
VIH_SE
HITH is low
HITH is high
Input Logic Low Voltage
VIL_SE
HITH is low
HITH is high
Input Hysteresis
ΔVITH_SE
Input Current (A, B, Z)
Input Current (A, B, Z)
Fault Threshold Voltage
I_HTL
I_HTL
VTH_HTLF
VCC = 0V or normally powered, VIN = 24V
VCC = 0V or normally powered, VIN = 24V
TTL RECEIVERS (RxA, RxB, RxZ, RxY, RxD2, RxD3)
Input High Voltage
VIH_TTL TTL mode
Input Low Voltage
VIL_TTL TTL mode
Input Hysteresis
VHY_TTL TTL mode
Input Current (A, B, Z, DIY, DI2,
DI3)
I_TTL
TTL mode, VCC = 0V or 5V, VIN = 5V
Input Current (A, B, Z, Y)
Fault Threshold Voltage
I_TTL
VTH_TTLF
TTL mode, VCC = 0V or 5V, VIN = 5V
Negative
Positive
DIGITAL INPUT RECEIVERS (DI2, DI3, RxY, RxZ)
Input High Voltage
Input Low Voltage
Input Hysteresis
VIH_DI
VIL_DI
VHY_DI
DI mode, HITH is high or low
DI mode, HITH is high or low
DI mode, HITH is high or low
MIN
+1.2
-2.0
-18
8
13
-40
-40
-18
2.0
-40
-18
+15
8
-40
TYP
270
0.53
1.2
MAX
+2.0
-1.2
-15
UNITS
V
V
40
V
40
6
V
11
mV
460
μA
460
μA
-15
V
40
V
0.8
V
V
85
μA
85
-15
V
+18
40
V
5.5
V
V
www.maximintegrated.com
Maxim Integrated │  3