Low-Current, SPI-Compatible Real-Time Clocks
AC ELECTRICAL CHARACTERISTICS
(VCC = +2.0V to +5.5V, TA = -40°C to +85°C. Typical values are at VCC = +3.3V, TA = +25°C, unless otherwise noted.) (Figure 5,
Notes 1, 5)
PARAMETER
SPI SERIAL TIMING
Input Rise Time
Input Fall Time
Output Rise Time
Output Fall Time
SCLK Period
SCLK High Time
SCLK Low Time
SCLK Fall to DOUT
Valid
DIN to SCLK Setup
Time
SYMBOL
CONDITIONS
trIN
tfIN
trOUT
tfOUT
tCP
tCH
tCL
tDO
tDS
DIN, SCLK, CS
DIN, SCLK, CS
DOUT, CLOAD = 100pF
DOUT, CLOAD = 100pF
VCC = +2V
VCC = +5V
VCC = +2V, CLOAD = 100pF
VCC = +5V, CLOAD = 100pF
MIN
TYP MAX UNITS
5
ns
5
ns
10
ns
10
ns
1000
ns
238
100
ns
100
ns
300
ns
100
100
ns
DIN to SCLK Hold
Time
SCLK Rise to CS
Rise Hold Time
CS High Pulse Width
CS High to DOUT
High Impedance
CS to SCLK Setup
Time
tDH
tCSH
tCSW
tCSZ
VCC = +2V
VCC = +5V
tCSS
20
ns
200
ns
50
200
ns
100
ns
100
ns
CRYSTAL CHARACTERISTICS
PARAMETER
Nominal Frequency
Series Resistance
Load Capacitance
SYMBOL
fO
ESR
CL
DS1346
DS1347
CONDITIONS
MIN
TYP MAX UNITS
32.768
kHz
100
k
6
pF
12.5
Note 1: All parameters are 100% tested at TA = +25°C. Limits over temperature are guaranteed by design and characterization and
not production tested.
Note 2: ICC is specified with DOUT open, CS = DIN = GND, SCLK = 4MHz at VCC = +5V; SCLK = 1MHz at VCC = +2.0V.
Note 3: Timekeeping current is specified with CS = VCC, SCLK = DIN = GND, DOSF = 0, EGFIL = 1.
Note 4: Guaranteed by design and not 100% production tested.
Note 5: All values referred to VIH(MIN) and VIL(MAX) levels.
_______________________________________________________________________________________ 3