MAX16047_09 Datasheet, PDF (22/61 Pages) Maxim Integrated Products – 12-Channel/8-Channel EEPROM-Programmable System Managers with Nonvolatile Fault Registers
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Any_Fault Outputs
GPIO1–GPIO4 are configurable as active-low push-pull
or open-drain fault-dependent outputs. These outputs
assert when any monitored input exceeds an overvolt-
age, undervoltage, or early warning threshold.
FAULT1 and FAULT2
GPIO5 and GPIO6 are configurable as dedicated fault
outputs, FAULT1 and FAULT2, respectively. Fault
outputs can assert on one or more overvoltage, under-
voltage, or early warning conditions for selected inputs.
FAULT1 and FAULT2 dependencies are set using reg-
isters r15h to r18h. See Table 7.
If a fault output depends on more than one MON_, the
fault output will assert if one or more MON_ exceeds a
programmed threshold voltage.
Table 7. FAULT1 and FAULT2 Output Configuration and Dependencies
REGISTER/
EEPROM
ADDRESS
15h
16h
17h
BIT RANGE
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
DESCRIPTION
1 = FAULT1 is a digital output dependent on MON1
1 = FAULT1 is a digital output dependent on MON2
1 = FAULT1 is a digital output dependent on MON3
1 = FAULT1 is a digital output dependent on MON4
1 = FAULT1 is a digital output dependent on MON5
1 = FAULT1 is a digital output dependent on MON6
1 = FAULT1 is a digital output dependent on MON7
1 = FAULT1 is a digital output dependent on MON8
1 = FAULT1 is a digital output dependent on MON9*
1 = FAULT1 is a digital output dependent on MON10*
1 = FAULT1 is a digital output dependent on MON11*
1 = FAULT1 is a digital output dependent on MON12*
1 = FAULT1 is a digital output that depends on the overvoltage thresholds at the input
selected by r15h and r16h[3:0]
1 = FAULT1 is a digital output that depends on the undervoltage thresholds at the
input selected by r15h and r16h[3:0]
1 = FAULT1 is a digital output that depends on the early warning thresholds at the
input selected by r15h and r16h[3:0]
0 = FAULT1 is an active-low digital output
1 = FAULT1 is an active-high digital output
1 = FAULT2 is a digital output dependent on MON1
1 = FAULT2 is a digital output dependent on MON2
1 = FAULT2 is a digital output dependent on MON3
1 = FAULT2 is a digital output dependent on MON4
1 = FAULT2 is a digital output dependent on MON5
1 = FAULT2 is a digital output dependent on MON6
1 = FAULT2 is a digital output dependent on MON7
1 = FAULT2 is a digital output dependent on MON8
22 ______________________________________________________________________________________