English
Language : 

MAX1661-MAX1663 Datasheet, PDF (2/16 Pages) Maxim Integrated Products – Serial-to-Parallel/Parallel-to-Serial Converters and Load-Switch Controllers with SMBus Interface
Serial-to-Parallel/Parallel-to-Serial Converters and
Load-Switch Controllers with SMBus Interface
ABSOLUTE MAXIMUM RATINGS
VCC to GND ..............................................................-0.3V to +6V
I/O to GND (I/O1, I/O2, I/O3) ..................................-0.3V to +30V
I/O Sink Current (I/O1, I/O2, I/O3),
Internally Limited.............................................-1mA to +50mA
Digital Inputs to GND (SMBCLK, SMBDATA,
SMBSUS, ALERT).................................................-0.3V to +6V
ADD to GND ...............................................-0.3V to (VCC + 0.3V)
SMBDATA Current, ALERT Current ....................-1mA to +50mA
Continuous Power Dissipation (TA = +70°C)
10-pin µMAX (derate 5.6mW/°C above +70°C) ...........444mW
Operating Temperature Range
MAX166_EUB ..................................................-40°C to +85°C
Storage Temperature Range .............................-65°C to +160°C
Lead Temperature (soldering, 10sec) .............................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = +2.7V to +5.5V, TA = TMIN to TMAX, unless otherwise noted. Typical values are for TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
Input Voltage Range
Supply Current
Static condition; SMBDATA, SMBCLK, ADD,
ALERT = VCC or GND (Note 2)
Undervoltage Lockout/
Power-On Reset Threshold
VCC falling
I/O Sink Current
I/O Current Limit
Thermal Shutdown
VI/O_ = 0.4V, VCC = 2.7V or 5.5V
VI/O_ = 1.0V, VCC = 4.5V
I/O1, I/O2, or I/O3; VCC = 4.5V
Typical hysteresis of 10°C
I/O Leakage Current
VI/O_ = 28V, high-impedance state
VI/O_ = 0V, VCC; high-impedance state
Digital Input Current
VSMBDATA, VSMBCLK, V SMBSUS,
VADD = 0V, VCC
SMBus Logic Input
Voltage Range
VCC = 2.7V to 5.5V;
SMBDATA, SMBCLK, SMBSUS
Logic Input High Voltage
Logic Input Low Voltage
I/O_, SMBSUS, SMBCLK, SMBDATA
I/O_, SMBSUS, SMBCLK, SMBDATA
SMBDATA Output Low Sink
Current
VSMBDATA = 0.6V
ALERT Output Low Sink Current
ALERT Output Leakage Current
SMBus Input Capacitance
V ALERT = 0.4V
V ALERT = 5.5V, high-Z state
SMBCLK, SMBDATA
SMBus Clock Frequency
(Notes 3, 4)
MIN TYP
2.7
3
1.2
1.6
2
8
13
15
20
140
0.5
-1
0.5
-1
0
2.4
6
1
5
SMBCLK High Time
tHIGH
Measured between the 90% level of the rising
edge and the 90% level of the falling edge
4
SMBCLK Low Time
tLOW
Measured between the 10% level of the falling
edge and the 10% level of the rising edge
4.7
MAX UNITS
5.5
V
10
µA
2.5
V
mA
50
mA
°C
5
µA
1
1
µA
5.5
V
V
0.8
V
mA
mA
1
µA
pF
100 kHz
µs
µs
2 _______________________________________________________________________________________