English
Language : 

MAX16125 Datasheet, PDF (2/16 Pages) Maxim Integrated Products – Dual Pushbutton Controllers
MAX16122–MAX16125
Dual Pushbutton Controllers in
Tiny 6-Bump WLP Package
ABSOLUTE MAXIMUM RATINGS
(All pins referenced to GND)
VCC...........................................................................-0.3V to +6V
RESET, SRESET to GND
Open-Drain...............................................................-0.3V to +6V
Push-Pull.................................................... -0.3V to (VCC + 0.3V)
MR, MR1, MR2.........................................................-0.3V to +6V
SEL...........................................................................-0.3V to +6V
Input/Output Current (all pins)............................................20mA
Continuous Power Dissipation (TA = +70NC) (Multilayer Board)
WLP (derate 10.5mW/NC above +70NC).......................840mW
Operating Temperature Range......................... -40NC to +125NC
Junction Temperature......................................................+150NC
Storage Temperature Range.............................-65NC to +150oC
Soldering Temperature (reflow).......................................+260NC
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional opera-
tion of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
PACKAGE THERMAL CHARACTERISTICS (Note 1)
WLP
Junction-to-Ambient Thermal Resistance (qJA)...........95°C/W
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-
layer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial.
ELECTRICAL CHARACTERISTICS
(VCC = 1.6V to 5.5V, TA = -40NC to +125NC, unless otherwise noted. Typical values are at TA = +25NC.) (Note 2)
PARAMETER
Operating Voltage Range
VCC Undervoltage Lockout
VCC Supply Current
Supply Current with Oscillator
Running
VCC Reset Threshold
VCC Reset Threshold Hysteresis
Reset Threshold Tempco
VCC to RESET Output Delay
Reset Timeout Period
Manual Reset Setup Delay
Debounce Period
SYMBOL
CONDITIONS
MIN
VCC
RESET state guaranteed for VCC R 0.95V
1.6
VCCUVLO
ICC
VCC = 5V, steady-state condition; MR, MR1,
MR2, RESET, and SRESET not asserted
TYP
1.25
8
MAX
5.5
1.55
UNITS
V
V
10
FA
ICC2
VCC = 3V
5
10
FA
VTH
VHYST
VCC falling
-2.5% VTH +2.5%
V
2
%
30
ppm/oC
tD
VCC falling at 10mV/Fs from (VTH + 100mV)
to (VTH - 100mV)
10
Fs
tRP
See Table 2
tSU
Internal timing (see Tables 1a, 1b, 1c)
tDB
-10
tRP
+10
%
-10
tSU
+10
%
18
20
22
ms
  2