English
Language : 

DS33R41 Datasheet, PDF (199/333 Pages) Maxim Integrated Products – Inverse-Multiplexing Ethernet Mapper with Quad Integrated T1/E1/J1 Transceivers
DS33R41 Inverse-Multiplexing Ethernet Mapper with Quad Integrated T1/E1/J1 Transceivers
Register Name:
Register Description:
Register Address:
TR.T1TCR1
T1 Transmit Control Register 1
05h
Bit #
7
Name
TJC
Default
0
6
5
4
3
2
1
TFPT
TCPT
TSSE
GB7S
TFDLS
TBL
0
0
0
0
0
0
0
TYEL
0
Bit 7: Transmit Japanese CRC6 Enable (TJC)
0 = use ANSI/AT&T/ITU CRC6 calculation (normal operation)
1 = use Japanese standard JT–G704 CRC6 calculation
Bit 6: Transmit F-Bit Pass-Through (TFPT)
0 = F bits sourced internally
1 = F bits sampled at TSERI
Bit 5: Transmit CRC Pass-Through (TCPT)
0 = source CRC6 bits internally
1 = CRC6 bits sampled at TSERI during F-bit time
Bit 4: Transmit Software Signaling Enable (TSSE)
0 = do not source signaling data from the TR.TSx registers regardless of the TR.SSIEx registers. The
TR.SSIEx registers still define which channels are to have B7 stuffing preformed.
1 = source signaling data as enabled by the TR.SSIEx registers
Bit 3: Global Bit 7 Stuffing (GB7S)
0 = allow the SSIEx registers to determine which channels containing all 0s are to be bit 7 stuffed
1 = force bit 7 stuffing in all 0-byte channels regardless of how the TR.SSIEx registers are programmed
Bit 2: TFDL Register Select (TFDLS)
0 = source FDL or Fs-bits from the internal TR.TFDL register (legacy FDL support mode)
1 = source FDL or Fs-bits from the internal HDLC controller
Bit 1: Transmit Blue Alarm (TBL)
0 = transmit data normally
1 = transmit an unframed all-ones code at TPOS and TNEG
Bit 0: Transmit Yellow Alarm (TYEL)
0 = do not transmit yellow alarm
1 = transmit yellow alarm