Table 3B. Time, Calendar, and Alarm Data Modes—Binary Mode (DM = 1)
ADDRESS BIT 7
BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
FUNCTION
RANGE
00h
0
0
Seconds
Seconds
00–3B
01h
0
0
Seconds
Seconds Alarm
00–3B
02h
0
0
Minutes
Minutes
00–3B
03h
0
0
AM/PM
04h
0
0
AM/PM
05h
0
0
0
0
0
0
Minutes
Hours
Hours
Hours
Hours
Minutes Alarm
Hours
Hours Alarm
00–3B
1–0C +AM/PM
00–17
1–0C +AM/PM
00–17
06h
0
0
0
0
0
Day
Day
01–07
07h
0
0
0
Date
Date
01–1F
08h
0
0
0
0
Month
Month
01–0C
09h
0
Year
Year
00–63
0Ah
UIP
DV2
DV1 DV0 RS3
RS2 RS1 RS0
Control
—
0Bh
SET
PIE
AIE
UIE SQWE DM 24/12 DSE
Control
—
0Ch
IRQF
PF
AF
UF
0
0
0
0
Control
—
0Dh
VRT
0
0
0
0
0
0
0
Control
—
Bank 1, 48h
10 Century
Century
Century
00–63
Bank 1, 49h
10 Date
Date
Date Alarm
01–1F
Note: Unless otherwise specified, the state of the registers is not defined when power is first applied. Except for the seconds regis-
ter, 0 bits in the time and date registers can be written to 1, but can be modified when the clock updates. 0 bits should always be
written to 0 except for alarm mask bits.
Control Registers
The four control registers (A, B, C, and D) reside in
both bank 0 and bank 1. These registers are accessi-
ble at all times, even during the update cycle.
Register A (0Ah)
MSB
BIT 7
UIP
BIT 6
DV2
BIT 5
DV1
BIT 4
DV0
Bit 7: Update In Progress (UIP). This bit is a status
flag that can be monitored. When the UIP bit is 1, the
update transfer will soon occur. When UIP is 0, the
update transfer does not occur for at least 244µs. The
time, calendar, and alarm information in RAM is fully
available for access when the UIP bit is 0. The UIP bit is
read-only. Writing the SET bit in Register B to 1 inhibits
any update transfer and clears the UIP status bit.
BIT 3
RS3
BIT 2
RS2
BIT 1
RS1
LSB
BIT 0
RS0
Bits 6, 5, and 4: DV2, DV1, and DV0. These bits are
used to turn the oscillator on or off and to reset the
countdown chain. A pattern of 01X is the only combina-
tion of bits that turns the oscillator on and allows the RTC
to keep time. A pattern of 11X enables the oscillator but
holds the countdown chain in reset. The next update
occurs at 500ms after a pattern of 01X is written to DV0,
DV1, and DV2. DV0 is used to select bank 0 or bank 1 as
defined in Table 5. When DV0 is set to 0, bank 0 is
selected. When DV0 is set to 1, bank 1 is selected.
14 ____________________________________________________________________