MAX13041_08 Datasheet, PDF (13/20 Pages) Maxim Integrated Products – ±80V Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN
±80V Fault-Protected High-Speed CAN Transceiver
with Low-Power Management and Wake-On CAN
PWON/LISTEN-ONLY MODE
STB = H AND EN = H
STB = H AND EN = L
NORMAL MODE
STB = H
AND EN = L
STB = L
AND
(EN = L OR
FLAG SET)
STB = H
AND EN = L
STB = L
AND EN = L
STB = H
AND EN = H
STB = H
AND EN = H
STB = L AND EN = H
AND FLAGS CLEARED
STB = L
AND EN = H
STANDBY MODE
STB = L AND EN = H
AND FLAGS CLEARED
GO-TO-SLEEP COMMAND MODE
STB = H AND EN = L
AND UVNOM CLEARED
STB = L AND
FLAG SET
STB = L AND
(EN = L OR FLAG SET)
FLAGS CLEARED
AND t > tH(MIN)
STB = H AND EN = H
AND UVNOM CLEARED
SLEEP MODE
NOTES: H AND L ARE
FLAG SET =
FLAGS CLEARED
LOGIC STATE OF EN OR STB
SETTING PWON AND/OR WAKE-UP FLAG.
PWON AND WAKE-UP FLAG BOTH CLEARED.
Figure 4. State Diagram
activity. To reduce power consumption, common-mode
stabilization is disabled. SPLIT becomes high imped-
ance, and CANH and CANL are biased to ground by
the termination resistors. INH goes high impedance,
disabling one or more external voltage regulators (see
Table 1.)
Flag Signaling
The MAX13041 uses a set of seven internal flags for
system diagnosis and to indicate faults. Five of the
flags are available at different times to the CAN proto-
col controller on ERR. A logic-low on ERR indicates a
set flag or a fault (see Table 3.) Allow ERR to stabilize
for at least 8µs after changing operating modes.
Supply Undervoltage: UVNOM
UVNOM is set when supply voltage on VCC drops below
VCC(SLEEP) for longer than tUV(Vcc), or when voltage on
VI/O drops below VI/O(SLEEP) for longer than tUV(VI/O).
When UVNOM is set, the MAX13041 enters low-power
sleep mode to reduce power consumption. The device
remains in sleep mode for a minimum waiting time
before allowing the UVNOM flag to be cleared. This
waiting time is determined by the same timer used for
setting UVNOM (tUV(VCC) or tUV(VIO).) UVNOM is cleared
by a local wake-up request triggered by a level change
on WAKE or by a wake-on-CAN event. UVNOM is also
cleared by setting the PWON flag.
VBAT Undervoltage: UVBAT
UVBAT is set when the voltage on VBAT drops below
VBAT(STB). When UVBAT is set, the MAX13041 enters
standby mode to reduce power consumption. UVBAT is
cleared when the voltage on VBAT is restored and
exceeds VBAT(STB). Upon clearing UVBAT, the
MAX13041 returns to the operating mode determined
by EN and STB.
Power-On Flag: PWON
PWON indicates the MAX13041 is in a power-on state.
PWON is set when VBAT has dropped below VBAT(STB)
and has subsequently recovered. This condition occurs
______________________________________________________________________________________ 13