DS1621 Datasheet, PDF (11/16 Pages) Dallas Semiconductor – Digital Thermometer and Thermostat
DS1621
Table 3. DS1621 COMMAND SET
INSTRUCTION
Read Temperature
Read Counter
Read Slope
Start Convert T
Stop Convert T
Access TH
Access TL
Access Config
2-WIRE BUS DATA
AFTER ISSUING
DESCRIPTION
PROTOCOL
PROTOCOL
TEMPERATURE CONVERSION COMMANDS
Read last converted temperature
AAh
<read 2 bytes data>
value from temperature register.
Reads value of Count_Remain
A8h
<read data>
Reads value of the
A9h
<read data>
Count_Per_C
Initiates temperature
EEh
idle
conversion.
Halts temperature conversion.
22h
idle
THERMOSTAT COMMANDS
Reads or writes high
A1h
<write data>
temperature limit value into TH
register.
Reads or writes low
A2h
<write data>
temperature limit value into TL
register.
Reads or writes configuration
ACh
<write data>
data to configuration register.
NOTES
1
1
2
2
2
NOTES:
1. In continuous conversion mode a Stop Convert T command will halt continuous conversion. To
restart the Start Convert T command must be issued. In one-shot mode a Start Convert T command
must be issued for every temperature reading desired.
2. Writing to the E2 requires a maximum of 10ms at room temperature. After issuing a write command,
no further writes should be requested for at least 10ms.
11 of 16