English
Language : 

MAX16134 Datasheet, PDF (10/23 Pages) Maxim Integrated Products – Low-Voltage, Precision, Single/Dual/Triple/Quad-Voltage μP Supervisors
MAX16132–MAX16135
Low-Voltage, Precision, Single/Dual/Triple/
Quad-Voltage μP Supervisors
Pin Description
MAX16132
PIN
MAX16133 MAX16134
1
1
1
MAX16135
1
2
—
—
—
3, 5, 6, 7
5, 6
—
—
4
4
4
4
8
—
—
—
—
2
2
2
—
3
3
3
—
7
7
7
—
8
8
8
NAME
VDD
IN
N.C.
GND
RESET
IN1
IN2
RESET2
RESET1
FUNCTION
Supply Input. Bypass with a 0.1µF capacitor to
GND.
Monitoring Input. Connect IN to its nominal input voltage.
When VIN falls outside overvoltage/undervoltage window
threshold, RESET asserts.
No Connect. Leave open or connect to ground.
Ground
Active-Low, Open-Drain Reset Output. RESET
asserts when VIN falls outside of the undervoltage/
overvoltage window threshold. RESET stays
asserted for the reset timeout period after VIN fall
within the undervoltage/overvoltage window threshold.
RESET requires a pullup resistor.
Monitoring Input 1. Connect IN1 to its nominal input
voltage. When VIN1 falls outside undervoltage/
overvoltage window threshold, RESET1 asserts.
For the quad input (MAX16135), RESET1 asserts
when either IN1 and/or IN2 falls outside the
undervoltage/overvotlage window threshold.
Monitoring Input 2. Connect IN2 to its nominal input
voltage. When VIN2 falls outside the undervoltage/
overvoltage window threshold, RESET2 asserts.
For the quad input (MAX16135), RESET1 asserts
when either IN2 and/or IN1 falls outside the
undervoltage/overvotlage window threshold.
Active-Low, Open-Drain Reset Output 2. RESET2
asserts when VIN2 falls outside the undervoltage/
overvoltage window threshold. RESET2 stays
asserted for the reset timeout period after VIN2
falls within the undervoltage/overvoltage window
threshold. RESET2 requires a pullup resistor. For
the MAX16135, RESET2 asserts when either IN3
and/or IN4 falls outside the undervoltage/
overvoltlage window threshold.
Active-Low, Open-Drain Reset Output 1. RESET1
asserts when VIN1 falls outside the undervoltage/
overvoltage window threshold. RESET1 stays
asserted for the reset timeout period after VIN1
falls within the undervoltage/overvoltage window
threshold. RESET1 requires a pull up resistor.For
the MAX16135, RESET1 asserts when either IN1
and/or IN2 falls outside the undervoltage/overvot-
lage window threshold.
www.maximintegrated.com
Maxim Integrated │  10